Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Journal of Long-Term Effects of Medical Implants
SJR: 0.145 SNIP: 0.491 CiteScore™: 0.89

ISSN Imprimir: 1050-6934
ISSN En Línea: 1940-4379

Journal of Long-Term Effects of Medical Implants

DOI: 10.1615/JLongTermEffMedImplants.v16.i2.40
pages 157-164

Bone Ingrowths to Press-Fit and Loose-Fit Implants: Comparisons between Titanium and Hydroxyapatite

Olav Reikeras
Institute of Clinical Medicine, Rikshospitalet University Clinic, University of Oslo, Oslo, Norway
Carina B. Johansson
Department of Biomaterials/Handicap Research, Sahlgrenska University Hospital, Institute for Surgical Sciences, University of Gothenburg, Gothenburg; and Department of Technology, University of Orebro, Orebro, Sweden
Mikael Sundfeldt
Department of Biomaterials/Handicap Research, Institute for Surgical Sciences, University of Göteborg; Department of Orthopaedics, Sahlgrenska University Hospital, Institute for Surgical Sciences, University of Göteborg, Sweden

SINOPSIS

The aim of this study was to investigate whether the coating of titanium (Ti) implants with hydroxyapatite (HA) might create a better fixation when titanium implants are implanted into a gap. In each of 16 rats, the medullary cavity of both femurs was entered by an awl from the trochanteric area. With steel burrs it was successively reamed to a diameter of 1.5 mm. In a random manner the proximal part of the cavity in half of the bones was reamed once again to a diameter of 2.0 mm. Nails with a diameter of 1.5 mm and a length of 34 mm were then inserted into the medullary cavity of these bones with press fit at the distal half and a gap to the bone in the proximal half. In the remaining bones the whole medullary canal was reamed to a diameter of 2.0 mm, and nails with a diameter of 2.0 mm and a length of 34 mm were introduced. In all cases, either a pure Ti nail or a Ti nail entirely plasma sprayed with HA was used in a random manner. The surface roughness of the pure Ti was characterized by Ra 2.6 μm and Rt 22 μm. Ra of HA was 7.5 μm and Rt 52 μm. At sacrifice after 16 weeks, both femurs were dissected free from soft tissues and then immersed in fixative. A specimen slice of about 5 mm in thickness was prepared from the subtrochanteric region with a water-cooled band saw. Sample preparation for undecalcified tissue followed the internal guidelines at the laboratories of the Department of Biomaterials/Handicap Research. Generally, bone contact to the nails with HA coating was more predictable than was bone contact to the Ti nails. But due to rather large variations in bone contact between the samples, statistical analyses revealed non-significant differences between the 4 groups (p = 0.083). There were no significant differences between Ti and HA coated nails of 2.0 mm (p = 0.633), nor between Ti and HA coated nails of 1.5 mm (p = 0.924). The pooled values for the 2.0 mm nails showed significantly higher bone bonding contact than the pooled values of the 1.5 mm nails (p = 0.011). Our results, then, indicate that bone bonding contact to implants with a loose fit insertion is less predictable than in press fit insertion, and HA coating seemed to be more predictable than pure Ti. However, due to large variations between the samples, the differences did not reach significant levels.


Articles with similar content:

Hydroxyapatite Enhances Long-Term Fixation of Titanium Implants
Journal of Long-Term Effects of Medical Implants, Vol.16, 2006, issue 2
Mikael Sundfeldt, Olav Reikeras, Carina B. Johansson
Hydroxyapatite and Carbon Coatings for Fixation of Unloaded Titanium Implants
Journal of Long-Term Effects of Medical Implants, Vol.14, 2004, issue 6
Mikael Sundfeldt, Olav Reikeras, Carina B. Johansson
Practice-Based Clinical Evaluation of Dental Implants Placed with Immediate or Delayed Loading Protocols: One-Year Follow-Up
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 2
Leonardo Rigoldi Bonjardim, Ernesto Byron Benalcazar Jalkh, Paulo Guilherme Coelho, Adolfo Coelho de Oliveira Lopes, Karin Hermana Neppelenbroek, Estevam Augusto Bonfante, Abbas Zahoui, Paulo Sérgio Perri de Carvalho de Carvalho
High Insertion Torque and Peri-Implant Bone Loss: Is There a Relationship?
Journal of Long-Term Effects of Medical Implants, Vol.25, 2015, issue 3
Mohsen Bidgoli, Javad Faradmal, Sepideh Soheilifar, Sara Soheilifar
Long-Term Follow-Up Study of Bioactive Bone Cement in Canine Total Hip Arthroplasty
Journal of Long-Term Effects of Medical Implants, Vol.16, 2006, issue 4
Takashi Nakamura, Kentaro Ise, Masashi Neo, Bojian Liang, Hiroshi Fujita, Shunsuke Fujibayashi