Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Journal of Long-Term Effects of Medical Implants
SJR: 0.145 SNIP: 0.491 CiteScore™: 0.89

ISSN Imprimir: 1050-6934
ISSN En Línea: 1940-4379

Journal of Long-Term Effects of Medical Implants

DOI: 10.1615/JLongTermEffMedImplants.v20.i1.60
pages 43-48

Evidence That In Vivo Wear Damage Alters Kinematics and Contact Stresses in a Total Knee Replacement

John L. Williams
University of Memphis, Department of Biomedical Engineering; InMotion Orthopaedic Research Center, Memphis TN, USA
David A. Knox
University of Memphis, Memphis, TN
Matthew G Teeter
Division of Orthopaedic Surgery, London Health Sciences Centre, London, Ontario, N6A 5A5, Canada
David W. Holdsworth
Imaging Research Laboratories, Robarts Research Institute; Department of Medical Biophysics; Division of Orthopaedic Surgery, The University of Western Ontario
William M. Mihalko
Department of Orthopaedic Surgery and Biomedical Engineering, School of Medicine, University of Tennessee Health Science Center, Memphis TN; Campbell Clinic Orthopedics, Germantown, TN

SINOPSIS

Polyethylene wear after a total knee arthroplasty is inevitable. The effects of the wear particles on the surrounding soft tissue causing inflammatory responses and eventual aseptic loosening are well documented, but the biomechanical changes from polyethylene wear have been less understood. This study investigated how wear from a retrieved polyethylene insert from a total knee arthroplasty changed the kinematics and contact stresses. A cruciate-retaining total knee implant (Natural-Knee, Intermedics Orthopedics, Inc., Austin, Texas) was retrieved from a donor program. The polyethylene insert was then scanned and modeled. KneeSIM (LifeMOD/KneeSIM, San Clemente, California) was used to simulate one cycle of gait of three second duration (100% of cycle). A threefold increase in contact stress as well as resulting kinematic changes were seen when the model was used to compare the retrieved versus a modeled off-the-shelf new polyethylene insert. Total knee designs should take into account the wear patterns that result from years of use and how they may affect the biomechanics of the knee long term.


Articles with similar content:

Biomechanical Analysis of CT Scan-based Hip Prosthesis With an Optimal Hip Ball by Using Finite Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 1
D. Sengupta, U.B. Ghosh, Amit Roychowdhury, S. Pal
Proposed Frequencies of a Vibrator Used for Implant Retrieval at the Time of Hip Joint Revision Surgery
Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 2
Vijay J. Rasquinha, Westley T. Hayes, Amit Roychowdhury
Histological Analysis of an Implant Retrieved from a β-Tricalcium Phosphate Graft after 4 Years: A Case Study
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 2
Rolf Ewers, Shadi Daher, Estevam Augusto Bonfante, Joseph Leary, Paulo G. Coelho
Stress and Strain Distribution Patterns in Bone around Splinted Standard and Short Implants Placed at the Crestal Level and Subcrestally using Three- Dimensional Finite Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.27, 2017, issue 1
Raheleh Akhavan Rasoolzadeh, Mahdi Kadkhodazadeh, Amir Mahmoudi Motlagh, Farshad Dehnavi, Reza Amid
Eosinophilic Metallosis: A Newly Described Entity in Failed Metal-on-Metal Arthroplasty
Journal of Long-Term Effects of Medical Implants, Vol.26, 2016, issue 4
A. Hanflik, E. Bryk, Brandon Levy, Vincent J. Vigorita