Follow-up Study of Gore-Tex® Artificial Ligament—Special Emphasis on Tunnel Osteolysis

Volumen 10, Edición 4, 2000, 12 pages
DOI: 10.1615/JLongTermEffMedImplants.v10.i4.50
Get accessGet access

SINOPSIS

The Gore-Tex anterior cruciate ligament has been implanted in 123 patients at our institutions between 1984 and 1993. The Gore-Tex ligaments were totally ruptured in 26 cases. In the remaining 97 cases, 80 were followed up 5-11 years after operation. Graft loosening occurred in half of the cases, and osteoarthritic change was developed in 62% of the cases. Moreover, tibial and tunnel osteolysis was observed in most of the cases. Judging from these follow-up results, the Gore-Tex ligament should not be used for anterior cruciate ligament reconstruction.

CITADO POR
  1. Chen Jimin, Xu Jiake, Wang Allan, Zheng Minghao, Scaffolds for tendon and ligament repair: review of the efficacy of commercial products, Expert Review of Medical Devices, 6, 1, 2009. Crossref

  2. Azangwe G, Aspden RM, Ligament and Tendon, Properties of, in Encyclopedia of Medical Devices and Instrumentation, 2006. Crossref

  3. Iorio Raffaele, Vadalà Antonio, Argento Giuseppe, Di Sanzo Vincenzo, Ferretti Andrea, Bone tunnel enlargement after ACL reconstruction using autologous hamstring tendons: a CT study, International Orthopaedics, 31, 1, 2007. Crossref

  4. Longo Umile Giuseppe, Lamberti Alfredo, Khan Wasim S., Maffulli Nicola, Denaro Vincenzo, Synthetic Augmentation for Massive Rotator Cuff Tears, Sports Medicine and Arthroscopy Review, 19, 4, 2011. Crossref

  5. Chen Tianwu, Jiang Jia, Chen Shiyi, Status and headway of the clinical application of artificial ligaments, Asia-Pacific Journal of Sports Medicine, Arthroscopy, Rehabilitation and Technology, 2, 1, 2015. Crossref

  6. Stewart Andrew M., Ahmad Christopher S., Failure of acromioclavicular reconstruction using Gore-Tex graft due to aseptic foreign-body reaction and clavicle osteolysis: A case report, Journal of Shoulder and Elbow Surgery, 13, 5, 2004. Crossref

  7. Colin F., Lintz F., Bargoin K., Guillard C., Venet G., Tesson A., Gouin F., Arthrite aseptique après reconstruction du LCA sur vis d’ancrage de ruban TLS® : à propos de deux cas, Revue de Chirurgie Orthopédique et Traumatologique, 98, 3, 2012. Crossref

  8. Miller Michael D., Peters Christopher L., Allen Bryce, Early Aseptic Loosening of a Total Knee Arthroplasty Due to Gore-Tex Particle–Induced Osteolysis, The Journal of Arthroplasty, 21, 5, 2006. Crossref

  9. Colin F., Lintz F., Bargoin K., Guillard C., Venet G., Tesson A., Gouin F., Aseptic arthritis after ACL reconstruction by Tape Locking Screw (TLS®): Report of two cases, Orthopaedics & Traumatology: Surgery & Research, 98, 3, 2012. Crossref

  10. Muren Olle, Dahlstedt Lars, Brosjö Eva, Dahlborn Mats, Dalén Nils, Gross osteolytic tibia tunnel widening with the use of Gore-Tex anterior cruciate ligament prosthesis, Acta Orthopaedica, 76, 2, 2005. Crossref

  11. Harris N. Lindsay, Indelicato Peter A., Bloomberg Mark S., Meister Keith, Wheeler Donna L., Radiographic and Histologic Analysis of the Tibial Tunnel after Allograft Anterior Cruciate Ligament Reconstruction in Goats, The American Journal of Sports Medicine, 30, 3, 2002. Crossref

  12. Germann Marco, Snedeker Jess G., Stalder Michael, Nuss Katja M., Meyer Dominik C., Farshad Mazda, Incorporating BMP-2 and skeletal muscle to a semitendinosus autograft in an oversized tunnel yields robust bone tunnel ossification in rabbits: Toward single-step revision of failed anterior cruciate ligament reconstruction, The Knee, 25, 5, 2018. Crossref

  13. Ker Dai Fei Elmer, Wang Dan, Behn Anthony William, Wang Evelyna Tsi Hsin, Zhang Xu, Zhou Benjamin Yamin, Mercado‐Pagán Ángel Enrique, Kim Sungwoo, Kleimeyer John, Gharaibeh Burhan, Shanjani Yaser, Nelson Drew, Safran Marc, Cheung Emilie, Campbell Phil, Yang Yunzhi Peter, Functionally Graded, Bone‐ and Tendon‐Like Polyurethane for Rotator Cuff Repair, Advanced Functional Materials, 28, 20, 2018. Crossref

  14. Matsumoto Tomohiro, Hattori Koji, Matsushima Asako, Tadokoro Mika, Yagyuu Takahiro, Kodama Makoto, Sato Junichi, Ohgushi Hajime, Osteogenic Potential of Mesenchymal Stem Cells on Expanded Polytetrafluoroethylene Coated with Both a Poly-Amino-Acid Urethane Copolymer and Collagen, Tissue Engineering Part A, 17, 1-2, 2011. Crossref

  15. Lamoria Ravindra, Sharma Arun, Goyal Divyanshu, Upadhyay Rahul, Influence of three different fixation methods on femoral tunnel widening in ACL reconstructed patients evaluated using computed tomography (CT) scan, European Journal of Orthopaedic Surgery & Traumatology, 30, 3, 2020. Crossref

  16. Sittinger M., Tissue engineering mesenchymaler Gewebe, in Tissue Engineering, 2003. Crossref

  17. Readings, in ACL Made Simple, 2004. Crossref

  18. Martin Robin, Nyland John, Jakob Roland Peter, ACL surgical innovation cycles: what goes around, comes around, Journal of ISAKOS, 5, 6, 2020. Crossref

  19. Wang Dan, Zhang Xu, Huang Shuting, Liu Yang, Fu Bruma Sai-chuen, Mak Kingston King-lun, Blocki Anna Maria, Yung Patrick Shu-hang, Tuan Rocky S., Ker Dai Fei Elmer, Engineering multi-tissue units for regenerative Medicine: Bone-tendon-muscle units of the rotator cuff, Biomaterials, 272, 2021. Crossref

2513 Vistas de artículos 14 Descargas de artículos Métrica
2513 PUNTOS DE VISTA 14 DESCARGAS 19 Crossref CITAS Google
Scholar
CITAS

Artículos con contenido similar:

A Review on Gore-Tex® Artificial Ligament—Special Emphasis on Tunnel Osteolysis Journal of Long-Term Effects of Medical Implants, Vol.27, 2017, issue 2-4
Toru Fukubayashi, Kohtaro Ikeda
Fourteen-Year Prospective Results of a High-Density Polyethylene Prosthetic Anterior Cruciate Ligament Reconstruction Journal of Long-Term Effects of Medical Implants, Vol.17, 2007, issue 1
Victor Hsu, Joseph Torg, Kenneth Rogers, Richard Mason, Robert Purchase, John P. Gaughan
Complications Following Short Femoral Nail Fixation for Intertrochanteric Hip Fractures: A Retrospective Study Journal of Long-Term Effects of Medical Implants, Vol.34, 2024, issue 4
Konstantinos Palaiologos, Spyridon J. Maris, Anastasia Vasilopoulou, Stavros Angelis, Antonios Trichonas, C. Grekas, Emmanouel Antonogiannakis, Alexandros P. Apostolopoulos, C. Nikakis, Efthymios J. Karadimas
Hip Pain and Pseudo-Lengthening of the Leg Due to Iliopsoas Haematoma Following Implantation of an Uncemented Component in Acetabular Cotyloplasty Technique Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 4
Raghavendra Prasad Sidaginamale, A. Manta, B. McConnell, Alexandros P. Apostolopoulos, G. Zafiropoulos
Radiographic and Clinical Outcomes Following Robotic-Assisted Lateral Unicompartmental Knee Arthroplasty Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 3
Sean A. Sutphen, Ray C. Wasielewski, David B. Johnson, Jr.

Próximos Artículos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones Precios y Políticas de Suscripcione Begell House Contáctenos Language English 中文 Русский Português German French Spain