Comparison of the Effects of Different Implant Apical Designs on the Magnitude and Distribution of Stress and Strain in Bone: A Finite Element Analysis Study

Mahdi Kadkhodazadeh
Dentofacial Deformities Research Center, Research Institute for Dental Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Ardeshir Lafzi
Department of Prosthdontics, Dental School, Shahid Behesti University of Medical Sciences, Tehran, Iran
Saeed Raoofi
Department of Periodontics, Dental Faculty, Shiraz University of Medical Sciences, Shiraz, Iran
Maryam Khademi
Department of Periodontics, Dental Faculty, Ahwaz University of Medical Sciences, Ahwaz, Iran
Reza Amid
Department of Periodontics, Dental School, Shahid Beheshti University of Medical Sciences, Evin, Tehran, Iran
Mohammad Reza Movahhedy
Manufacturing, Sharif University of Technology, Tehran, Iran
Hasti Torabi
Department of Periodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran, Iran

SINOPSIS

Objectives: The aim of this study was to investigate the effects of implant design on the apex area and on stress and stress patterns within surrounding bone. Methods: Three commercially available implants with the same diameter (3.5 mm), same length (10−11 mm), and same complement abutment were selected for modeling as follows: (1) flat apical design with light tapering degree, (2) dome-shaped apical design with light tapering, and (3) flat apical design with intense tapering in one-third of the apical area. According to human conebeam computed tomography (CBCT), the bone was modeled using a cortical thickness of 2 mm and cancellous bone. Forces of 100 N and 300 N in the vertical and 15° angle directions were applied to the entire abutment surface, and the equivalent stress and strain were calculated using finite element analysis (FEA) methods. Results: In all models, stress was concentrated on the cortical bone around the implant neck; in non-axial loads, stress was concentrated on the buccal side. The maximum strain recorded was a microstrain of 7200 μm μm−1 around the apex of sample C, which also showed the highest level of stress detected in cancellous bone (4.4 MPa). We observed the pathologic overload in the apical area of sample B (with a dome-shaped apex); however, the strain value was less than that of sample C. Conclusion: FEA revealed that great sudden changes in diameter along the fixture increases stress and strain in peri-implant bone. Therefore, uniform tapering should be considered as a standard feature for most clinical situations, and a flat apical design, which creates a better stress and strain distribution in surrounding bone than dome-shaped bone, should also be used.


Articles with similar content:

Stress and Strain Distribution Patterns in Bone around Splinted Standard and Short Implants Placed at the Crestal Level and Subcrestally using Three- Dimensional Finite Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.27, 2017, issue 1
Raheleh Akhavan Rasoolzadeh, Mahdi Kadkhodazadeh, Amir Mahmoudi Motlagh, Farshad Dehnavi, Reza Amid
Comparison of Stress Distribution in Alveolar Bone with Different Implant Diameters and Vertical Cantilever Length via the Finite Element Method
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 1
Mahsa Rashidpour, Niloufar Ahmadian, Ashraf Sayyedi, Mohammad Dehghan, Paniz Fasih, Forouzan Faghani, Amir Fayyaz
Effect of Implant-Abutment Connection Type on Stress Distribution in Peri-Implant Bone and Abutment Micromovement: A Three-Dimensional Finite Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 2
Fariborz Vafaee, Masoumeh Khoshhal, Narges Panahandeh, Parviz Torkzaban, Bahman Tootiaee, Narges Ziaei
Stress and Strain Distribution Patterns in Bone around Tissue- and Bone-Level Implant-Supported Mandibular Overdentures Using Three-Dimensional Finite-Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 3
Farhad Hajizadeh, Sanaz Panahi
Heat Caused by Dental Implant Fixture Seating: Temperature In Vitro and Software Simulation
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 4
Afsaneh Akhavan Tafti, Farhood Massoumi, Seyedeh Mehrnaz Mirdehghan