Optimization of Spinal Implant Screw for Lower Vertebra through Finite Element Studies

Jayanta Kumar Biswas
Indian Institute of Engineering Science and Technology
Santanu Kr. Karmakar
Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology, Shibpur, Howrah-711103, India
Santanu Majumder
Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur, Howrah–711103, India
Partha Sarathi Banerjee
Central Mechanical Engineering Research Institute, Durgapur
Subrata Saha
Affiliate Professor, Department of Restorative Dentistry Affiliate Instructor, Department of Oral and Maxillofacial Surgery School of Dentistry, University of Washington, Seattle, Washington 98195-6365, USA; Courtesy Professor, Department of Biomedical Engineering, Florida International University, Miami, Florida 33174, USA
Amit Roychowdhury
Department of Aerospace Engineering and Applied Mechanics, Indian Institute of Engineering Science and Technology, Shibpur, India

SINOPSIS

The increasing older population is suffering from an increase in age-related spinal degeneration that causes tremendous pain. Spine injury is mostly indicated at the lumbar spine (L3−L5) and corresponding intervertebral disks. Finite element analysis (FEA) is now one of the most efficient and accepted tools used to simulate these pathological conditions in computer-assisted design (CAD) models. In this study, L3−L5 spines were modeled, and FEA was performed to formulate optimal remedial measures. Three different loads (420, 490.5, and 588.6 N) based on three body weights (70, 90, and 120 kg) were applied at the top surface of the L3 vertebra, while the lower surface of the L5 vertebra remained fixed. Models of implants using stainless steel and titanium alloy (Ti6Al4V) pedicle screws and rods with three different diameters (4, 5, and 6 mm) were inserted into the spine models. The relative strengths of bone (very weak, weak, standard, strong, and very strong) were considered to determine the patient-specific effect. A total of 90 models were simulated, and von Mises stress and strain, shear stress, and strain intensity contour at the bone-implant interface were analyzed. Results of these analyses indicate that the 6-mm pedicle screw diameter is optimal for most cases. Experimental and clinical validation are needed to confirm these theoretical results.


Articles with similar content:

Biomechanical Analysis of CT Scan-based Hip Prosthesis With an Optimal Hip Ball by Using Finite Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 1
D. Sengupta, U.B. Ghosh, Amit Roychowdhury, S. Pal
A 3-D FEM Analysis of Single and Multiple Screw-Root Dental Implant Fixed in a Mandible
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 3&4
Amit Roychowdhury, S. Pal
Heat Caused by Dental Implant Fixture Seating: Temperature In Vitro and Software Simulation
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 4
Afsaneh Akhavan Tafti, Farhood Massoumi, Seyedeh Mehrnaz Mirdehghan
Proposed Frequencies of a Vibrator Used for Implant Retrieval at the Time of Hip Joint Revision Surgery
Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 2
Vijay J. Rasquinha, Westley T. Hayes, Amit Roychowdhury
A Long Term Histological Analysis of Effect of Interposed Hydroxyapatite between Bone and Bone Cement in THA and TKA
Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 2
Hironobu Oonishi