Volumen 46, 2019 Volumen 45, 2018 Volumen 44, 2017 Volumen 43, 2016 Volumen 42, 2015 Volumen 41, 2014 Volumen 40, 2013 Volumen 39, 2012 Volumen 38, 2011 Volumen 37, 2010 Volumen 36, 2009 Volumen 35, 2008 Volumen 34, 2007 Volumen 33, 2006 Volumen 32, 2005 Volumen 31, 2004 Volumen 30, 2003 Volumen 29, 2002 Volumen 28, 2001 Volumen 27, 2000 Volumen 26, 1999 Volumen 25, 1998 Volumen 24, 1997 Volumen 23, 1996 Volumen 22, 1995

International Journal of Fluid Mechanics Research

DOI: 10.1615/InterJFluidMechRes.2017018766
pages 409-425

THE ROLE OF AN ELECTRICALLY HEATED FRONT COVER ON THE THERMAL PERFORMANCE OF A RADIATOR

Francesco Corvaro
Dipartimento di Ingegneria Industriale e Scienze Matematiche (DIISM), Università Politecnica delle Marche, Ancona, Italy
Maurizio Benucci
Dipartimento di Ingegneria Industriale e Scienze Matematiche (DIISM), Università Politecnica delle Marche, Ancona, Italy
Barbara Marchetti
Facoltà di Ingegneria - Università degli Studi eCampus, Novedrate (CO), Italy
Roberta Cocci Grifoni
School of Architecture and Design, Università di Camerino, Camerino (MC), Italy
Fabio Polonara
Dipartimento di Ingegneria Industriale e Scienze Matematiche (DIISM), Università Politecnica delle Marche, Ancona, Italy

ABSTRAKT

The main aim of this work was to assess the possible improvements on the thermal performances of a central body radiator converted in a convector by the addition of a convex electrically heated front cover. A three-dimensional steady-state numerical analysis was performed using computational fluid dynamics (CFD) simulations. The laminar flow regime was analyzed; a T-shaped finned central body temperature of 50°C and inlet air temperature of 19°C were imposed for all cases. The velocity and temperature distribution of air were evaluated at the inlet, central, and outlet sections for inactive cover and for four other different temperatures. Performances of the convector were investigated through energetic and exergetic analysis. For low cover temperatures a recirculation zone affects the plane-convex volume and turns into a localized inversion flow for increasing temperatures. Velocity and temperature profiles of air in the inlet, central, and outlet sections show that only the volume between the front cover and central body is significantly influenced by the temperature variation of the electrical resistance. A homogeneous temperature and velocity profile in the outlet section was achieved for thermal resistance temperatures of 50°C and 60°C.


Articles with similar content:

A NUMERICAL STUDY OF HEAT TRANSFER AND PRESSURE DROP IN NANOFLUIDS FLOW BETWEEN PARALLEL PLATES
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2015, issue
Partha S. Ghoshdastidar, Sahil Arora
PERFORMANCE CHARACTERISTICS OF PULSATING HEAT PIPE WITH VARIOUS NON-UNIFORM HEATING CONDITIONS
International Heat Transfer Conference 16, Vol.13, 2018, issue
Kyeongsoo Song, Dong Soo Jang, Yongchan Kim, Junyub Lim, Wonhee Cho
EXPERIMENTAL CHARACTERIZATION OF A DOUBLE BACK TO BACK PULSATING HEAT PIPE FOR POWER ELECTRONICS
Heat Pipe Science and Technology, An International Journal, Vol.6, 2015, issue 3-4
Mathieu Habert, Bruno Agostini
ANALYSIS OF THE EFFECT OF THE STRUCTURE OF A CAPILLARY PUMPED LOOP ON TEMPERATURE OF DUAL CPUs 1U CLOUD SERVERS
Heat Transfer Research, Vol.44, 2013, issue 1
Wei-Keng Lin, Yeun-Ming Tzou, Yu-An Lin
ANALYSIS OF WATER CIRCULATION IN BOILERS UNDER STEADY-STATE CONDITIONS
Computational Thermal Sciences: An International Journal, Vol.3, 2011, issue 4
Hassan M. Badr, Mohamed A. Habib, Syed-Ahmad M. Said, S. Al-Anizi, Rached Ben-Mansour