Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
International Journal of Fluid Mechanics Research
ESCI SJR: 0.206 SNIP: 0.446 CiteScore™: 0.5

ISSN Druckformat: 2152-5102
ISSN Online: 2152-5110

Volumes:
Volumen 46, 2019 Volumen 45, 2018 Volumen 44, 2017 Volumen 43, 2016 Volumen 42, 2015 Volumen 41, 2014 Volumen 40, 2013 Volumen 39, 2012 Volumen 38, 2011 Volumen 37, 2010 Volumen 36, 2009 Volumen 35, 2008 Volumen 34, 2007 Volumen 33, 2006 Volumen 32, 2005 Volumen 31, 2004 Volumen 30, 2003 Volumen 29, 2002 Volumen 28, 2001 Volumen 27, 2000 Volumen 26, 1999 Volumen 25, 1998 Volumen 24, 1997 Volumen 23, 1996 Volumen 22, 1995

International Journal of Fluid Mechanics Research

DOI: 10.1615/InterJFluidMechRes.v25.i4-6.210
pages 689-698

Heat Transfer Characteristics of a Finned Horizontal Tube in a FBC

Tae Yong Chung
Department of Mechanical Engineering, Kookmin University, Seoul 132-720, KOREA
Jae Ou Chae
Department of Mechanical Engineering, Inha University, Inchon 420-020, KOREA
Pyung Sam Ji
New Energy Section, Power Generation Department, Research Center, KEPCO, 117-15, Yongjeon-Dong, Dong-ku, Taejon 300-200, KOREA

ABSTRAKT

This study is to investigate the characteristics of heat transfer of a horizontal tube, equipped with radial fins of triangular profile, immersed in a high-temperature fluidized bed. The heat transfer variations are compared with those of a smooth tube experimentally.
The finned tubes and smooth tube, with outside and inside diameters of 48.6 mm and 30.6 mm, are made of steel. The depth of the fin is 5 mm and the angles of fin are 25°, 30°, 35°, 40°, 45°, and 50°. Experiments are conducted at three different bed temperatures of 720, 800 and 880°C. A granular refractory (silica sand) is used as bed material with mean particle diameters of 0.96 mm and 1.37 mm.
The maximum heat transfer coefficient is achieved by the rake angle of 25° for the particle size 0.96 mm of bed material, and by the rake angle of 30° for the particle size 1.37 min. These coefficients are about 2 and 1.8 times higher than the case for the smooth tube, respectively. The heat transfer coefficient for the finned tube is greater than that for the smooth tube. Also the rake angle of the finned tube for the maximum heat transfer coefficient changes depending on the particle size of bed material, and the effect of the rake angle becomes more distinct as the bed temperature increases.


Articles with similar content:

HEAT TRANSFER CHARACTERISTICS OF A FINNED HORIZONTAL TUBE IN A FBC
Transport Phenomena in Thermal Engineering. Volume 2, Vol.0, 1993, issue
Jae Ou Chae, Tae Yong Chung, Pyung Sam Ji
THE EFFECT OF TURBULENCE PROMOTERS ON HEAT AND MOMENTUM TRANSFER FOR AIR FLOW IN AN ANNULUS
International Heat Transfer Conference 4, Vol.9, 1970, issue
J. J. C. Picot , C. K. Rao
HEAT TRANSFER TO HORIZONTAL FINNED TUBE BUNDLES IN THE FREEBOARD REGION OF FLUIDIZED BED
Transport Phenomena in Thermal Engineering. Volume 2, Vol.0, 1993, issue
Y. Katoh, Y. Idei, Masahide Miyamoto
HEAT TRANSFER AND HYDRAULIC RESISTANCE IN SINGLE-PHASE FORCED CONVECTION IN ANNULAR CHANNELS WITH TWISTING WIRE INSERTS
Journal of Enhanced Heat Transfer, Vol.20, 2013, issue 6
Anatoly B. Yakovlev
Heat Transfer and Hydraulic Resistance in Rod Bundles of Tubes with Counter Wire-Winding in Longitudinal Flow
Heat Transfer Research, Vol.32, 2001, issue 7&8
Benediktas B. Cesna