Abo Bibliothek: Guest
Critical Reviews™ in Biomedical Engineering

Erscheint 6 Ausgaben pro Jahr

ISSN Druckformat: 0278-940X

ISSN Online: 1943-619X

SJR: 0.262 SNIP: 0.372 CiteScore™:: 2.2 H-Index: 56

Indexed in

Opportunities and Challenges of 7 Tesla Magnetic Resonance Imaging: A Review

Volumen 44, Ausgabe 1-2, 2016, pp. 73-89
DOI: 10.1615/CritRevBiomedEng.2016016365
Get accessGet access

ABSTRAKT

The desire to achieve clinical ultra-high magnetic resonance imaging (MRI) systems stems from the fact that higher field strength leads to higher signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and spatial resolution. During last few years 7T MRI systems have become a quasi standard for ultra-high field MRI (UhFMRI) systems. This review presents a detailed account of opportunities and challenges associated with a clinical 7T MRI system for cranial and extracranial imaging. As with all of the previous transitions to higher field strengths, the switch from high to UhFMRI is not easy. The engineering and scientific community have to overcome challenges like magnetic field inhomogeneity, patient safety and comfort issues, and cost and related problems in order to achieve a clinically viable UhFMRI system. In addition, a large number of clinical studies are still required to show the improvements in quality of diagnostics that would come with 7T MRI, in order to bring such a research tool to the clinic.

REFERENZIERT VON
  1. Menon Rajiv G., Chang Gregory, Regatte Ravinder R., The Emerging Role of 7 Tesla MRI in Musculoskeletal Imaging, Current Radiology Reports, 6, 8, 2018. Crossref

  2. Ashrafi Akbar N., Tafuri Alessandro, Cacciamani Giovanni E., Park Daniel, de Castro Abreu Andre Luis, Gill Inderbir S., Focal therapy for prostate cancer, Current Opinion in Urology, 28, 6, 2018. Crossref

  3. Sneag Darryl B., Zochowski Kelly C., Tan Ek T., Queler Sophie C., Burge Alissa, Endo Yoshimi, Lin Bin, Fung Maggie, Shin Jaemin, Denoising of diffusion MRI improves peripheral nerve conspicuity and reproducibility, Journal of Magnetic Resonance Imaging, 51, 4, 2020. Crossref

  4. Maruyama Shuki, Fukunaga Masaki, Fautz Hans-Peter, Heidemann Robin, Sadato Norihiro, Comparison of 3T and 7T MRI for the visualization of globus pallidus sub-segments, Scientific Reports, 9, 1, 2019. Crossref

  5. Guensch Dominik P., Fischer Kady, Jung Christof, Hurni Samuel, Winkler Bernhard M., Jung Bernd, Vogt Andreas P., Eberle Balthasar, Lionetti Vincenzo, Relationship between myocardial oxygenation and blood pressure: Experimental validation using oxygenation-sensitive cardiovascular magnetic resonance, PLOS ONE, 14, 1, 2019. Crossref

  6. ElMallah Mohammed K., Seibold Leonard K., Kahook Malik Y., Williamson Blake K., Singh Inder P., Dorairaj Syril K., 12-Month Retrospective Comparison of Kahook Dual Blade Excisional Goniotomy with Istent Trabecular Bypass Device Implantation in Glaucomatous Eyes at the Time of Cataract Surgery, Advances in Therapy, 36, 9, 2019. Crossref

  7. Lazik-Palm Andrea, Kraff Oliver, Rietsch Stefan H. G., Ladd Mark E., Kamminga Michael, Beck Sascha, Quick Harald H., Theysohn Jens M., 7-T clinical MRI of the shoulder in patients with suspected lesions of the rotator cuff, European Radiology Experimental, 4, 1, 2020. Crossref

  8. Gonzalez‐Escamilla Gabriel, Ciolac Dumitru, De Santis Silvia, Radetz Angela, Fleischer Vinzenz, Droby Amgad, Roebroeck Alard, Meuth Sven G., Muthuraman Muthuraman, Groppa Sergiu, Gray matter network reorganization in multiple sclerosis from 7‐Tesla and 3‐Tesla MRI data, Annals of Clinical and Translational Neurology, 7, 4, 2020. Crossref

  9. Straub Sina, Mangesius Stephanie, Emmerich Julian, Indelicato Elisabetta, Nachbauer Wolfgang, Degenhardt Katja S., Ladd Mark E., Boesch Sylvia, Gizewski Elke R., Toward quantitative neuroimaging biomarkers for Friedreich's ataxia at 7 Tesla: Susceptibility mapping, diffusion imaging, R 2 and R 1 relaxometry , Journal of Neuroscience Research, 98, 11, 2020. Crossref

  10. Esmaeili Morteza, Strasser Bernhard, Bogner Wolfgang, Moser Philipp, Wang Zhe, Andronesi Ovidiu C., Whole‐Slab 3D MR Spectroscopic Imaging of the Human Brain With Spiral‐Out‐In Sampling at 7T , Journal of Magnetic Resonance Imaging, 53, 4, 2021. Crossref

  11. Menon Rajiv G., Chang Gregory, Regatte Ravinder R., Musculoskeletal MR Imaging Applications at Ultra-High (7T) Field Strength, Magnetic Resonance Imaging Clinics of North America, 29, 1, 2021. Crossref

  12. Kirsch Claudia F., Ho Mai-Lan, Advanced Magnetic Resonance Imaging of the Skull Base, Seminars in Ultrasound, CT and MRI, 42, 3, 2021. Crossref

  13. Assessment of Human Brain Using MRI, in Dental Neuroimaging, 2022. Crossref

  14. Cacciamani Giovanni E., De Castro Abreu Andre L., Chen Andrew, Saha Mihir, Falagario Ugo, Zukovksi Eduardo B., Autorino Riccardo, Use of Multiparametrric Magnetic Resonance Imaging (mpMRI) for Prostate Cancer: A Journey from 1.5 to 10 Tesla, in Anatomy for Urologic Surgeons in the Digital Era, 2021. Crossref

  15. Soldati Enrico, Rossi Francesca, Vicente Jerome, Guenoun Daphne, Pithioux Martine, Iotti Stefano, Malucelli Emil, Bendahan David, Survey of MRI Usefulness for the Clinical Assessment of Bone Microstructure, International Journal of Molecular Sciences, 22, 5, 2021. Crossref

  16. Soldati Enrico, Pithioux Martine, Guenoun Daphne, Bendahan David, Vicente Jerome, Assessment of Bone Microarchitecture in Fresh Cadaveric Human Femurs: What Could Be the Clinical Relevance of Ultra-High Field MRI, Diagnostics, 12, 2, 2022. Crossref

  17. Frey Jessica, Cagle Jackson, Johnson Kara A., Wong Joshua K., Hilliard Justin D., Butson Christopher R., Okun Michael S., de Hemptinne Coralie, Past, Present, and Future of Deep Brain Stimulation: Hardware, Software, Imaging, Physiology and Novel Approaches, Frontiers in Neurology, 13, 2022. Crossref

  18. Guo Xiaopeng, Yao Shun, Xing Bing, Letter to the Editor. Is 7-Tesla MRI necessary in the assessment of microstructural injury to visual pathways due to pituitary adenomas?, Journal of Neurosurgery, 132, 2, 2020. Crossref

  19. YILMAZ Selmi, Dental and Maxillofacial Magnetic Resonance Imaging; an update, Selcuk Dental Journal, 2022. Crossref

  20. Meyer Nolan K, Kang Daehun, Black David F, Campeau Norbert G, Welker Kirk M, Gray Erin M, In Myung-Ho, Shu Yunhong, Huston III John, Bernstein Matt A, Trzasko Joshua D, Enhanced clinical task-based fMRI metrics through locally low-rank denoising of complex-valued data, The Neuroradiology Journal, 2022. Crossref

  21. Clément Jérémie, Tomi-Tricot Raphaël, Malik Shaihan J., Webb Andrew, Hajnal Joseph V., Ipek Özlem, Towards an integrated neonatal brain and cardiac examination capability at 7 T: electromagnetic field simulations and early phantom experiments using an 8-channel dipole array, Magnetic Resonance Materials in Physics, Biology and Medicine, 35, 5, 2022. Crossref

  22. Zhang Yunfei, Yang Chun, Liang Liang, Shi Zhang, Zhu Shuo, Chen Caizhong, Dai Yongming, Zeng Mengsu, Preliminary Experience of 5.0 T Higher Field Abdominal Diffusion‐Weighted MRI : Agreement of Apparent Diffusion Coefficient With 3.0 T Imaging , Journal of Magnetic Resonance Imaging, 56, 4, 2022. Crossref

  23. Zheng Liyun, Yang Chun, Sheng Ruofan, Dai Yongming, Zeng Mengsu, Renal imaging at 5 T versus 3 T: a comparison study, Insights into Imaging, 13, 1, 2022. Crossref

Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen Preise und Aborichtlinien Begell House Kontakt Language English 中文 Русский Português German French Spain