Motion Compensation Strategies in Magnetic Resonance Imaging

Volumen 40, Ausgabe 2, 2012, pp. 99-119
DOI: 10.1615/CritRevBiomedEng.v40.i2.20
Get accessGet access

ABSTRAKT

Image quality in magnetic resonance imaging (MRI) is considerably affected by motion. Therefore, motion is one of the most common sources of artifacts in contemporary cardiovascular MRI. Such artifacts in turn may easily lead to misinterpretations in the images and a subsequent loss in diagnostic quality. Hence, there is considerable research interest in strategies that help to overcome these limitations at minimal cost in time, spatial resolution, temporal resolution, and signal-to-noise ratio. This review summarizes and discusses the three principal sources of motion: the beating heart, the breathing lungs, and bulk patient movement. This is followed by a comprehensive overview of commonly used compensation strategies for these different types of motion. Finally, a summary and an outlook are provided.

REFERENZIERT VON
  1. Pazahr Shila, Boss Andreas, Rossi Cristina, Clinical Functional MRI of the kidneys, Current Radiology Reports, 1, 2, 2013. Crossref

  2. Driessen Mieke M. P., Breur Johannes M. P. J., Budde Ricardo P. J., van Oorschot Joep W. M., van Kimmenade Roland R. J., Sieswerda Gertjan Tj, Meijboom Folkert J., Leiner Tim, Advances in cardiac magnetic resonance imaging of congenital heart disease, Pediatric Radiology, 45, 1, 2015. Crossref

  3. Velde Greetje Vande, De Langhe Ellen, Poelmans Jennifer, Dresselaers Tom, Lories Rik J., Himmelreich Uwe, Magnetic Resonance Imaging for Noninvasive Assessment of Lung Fibrosis Onset and Progression, Investigative Radiology, 49, 11, 2014. Crossref

  4. Coppo Simone, Firsova Maria, Locca Didier, Knebel Jean-François, van Heeswijk Ruud B., Stuber Matthias, Repositioning precision of coronary arteries measured on X-ray angiography and its implications for coronary MR angiography, Journal of Magnetic Resonance Imaging, 41, 5, 2015. Crossref

  5. Coppo Simone, Piccini Davide, Bonanno Gabriele, Chaptinel Jérôme, Vincenti Gabriella, Feliciano Hélène, van Heeswijk Ruud B., Schwitter Juerg, Stuber Matthias, Free-running 4D whole-heart self-navigated golden angle MRI: Initial results, Magnetic Resonance in Medicine, 74, 5, 2015. Crossref

  6. Coristine Andrew J., van Heeswijk Ruud B., Stuber Matthias, Combined T2-preparation and two-dimensional pencil-beam inner volume selection, Magnetic Resonance in Medicine, 74, 2, 2015. Crossref

  7. Moulin Kevin, Croisille Pierre, Feiweier Thorsten, Delattre Benedicte M.A., Wei Hongjiang, Robert Benjamin, Beuf Olivier, Viallon Magalie, In vivo free-breathing DTI and IVIM of the whole human heart using a real-time slice-followed SE-EPI navigator-based sequence: A reproducibility study in healthy volunteers, Magnetic Resonance in Medicine, 76, 1, 2016. Crossref

  8. Kaza E, Symonds-Tayler R, Collins D J, McDonald F, McNair H A, Scurr E, Koh D-M, Leach M O, First MRI application of an active breathing coordinator, Physics in Medicine and Biology, 60, 4, 2015. Crossref

  9. Fair Merlin J., Gatehouse Peter D., DiBella Edward V. R., Firmin David N., A review of 3D first-pass, whole-heart, myocardial perfusion cardiovascular magnetic resonance, Journal of Cardiovascular Magnetic Resonance, 17, 1, 2015. Crossref

  10. Ginami Giulia, Bonanno Gabriele, Schwitter Juerg, Stuber Matthias, Piccini Davide, An iterative approach to respiratory self-navigated whole-heart coronary MRA significantly improves image quality in a preliminary patient study, Magnetic Resonance in Medicine, 75, 4, 2016. Crossref

  11. Catana Ciprian, Motion Correction Options in PET/MRI, Seminars in Nuclear Medicine, 45, 3, 2015. Crossref

  12. Heeswijk Ruud B. van, Gonzales Christine, Schwitter Juerg, Chapter 7 Cardiac Disease, in Fluorine Magnetic Resonance Imaging, 2016. Crossref

  13. Rank Christopher M., Heußer Thorsten, Buzan Maria T. A., Wetscherek Andreas, Freitag Martin T., Dinkel Julien, Kachelrieß Marc, 4D respiratory motion-compensated image reconstruction of free-breathing radial MR data with very high undersampling, Magnetic Resonance in Medicine, 77, 3, 2017. Crossref

  14. Chaptinel Jerome, Piccini Davide, Bonanno Gabriele, Coppo Simone, Monney Pierre, Stuber Matthias, Schwitter Juerg, Respiratory optimized data selection for more resilient self-navigated whole-heart coronary MR angiography, Magnetic Resonance Materials in Physics, Biology and Medicine, 30, 3, 2017. Crossref

  15. Piekarski Eve, Chitiboi Teodora, Ramb Rebecca, Latson Larry A., Bhatla Puneet, Feng Li, Axel Leon, Two-dimensional XD-GRASP provides better image quality than conventional 2D cardiac cine MRI for patients who cannot suspend respiration, Magnetic Resonance Materials in Physics, Biology and Medicine, 31, 1, 2018. Crossref

  16. Bonanno Gabriele, Hays Allison G., Weiss Robert G., Schär Michael, Self-gated golden angle spiral cine MRI for coronary endothelial function assessment, Magnetic Resonance in Medicine, 80, 2, 2018. Crossref

  17. To David T., Kim Joshua P., Price Ryan G., Chetty Indrin J., Glide-Hurst Carri K., Impact of incorporating visual biofeedback in 4D MRI, Journal of Applied Clinical Medical Physics, 17, 3, 2016. Crossref

  18. Stemkens Bjorn, Benkert Thomas, Chandarana Hersh, Bittman Mark E., Van den Berg Cornelis A.T., Lagendijk Jan J.W., Sodickson Daniel K., Tijssen Rob H.N., Block Kai Tobias, Adaptive bulk motion exclusion for improved robustness of abdominal magnetic resonance imaging, NMR in Biomedicine, 30, 11, 2017. Crossref

  19. Thomas David H, Santhanam Anand, Kishan Amar U, Cao Minsong, Lamb James, Min Yugang, O'Connell Dylan, Yang Yingli, Agazaryan Nzhde, Lee Percy, Low Daniel, Initial clinical observations of intra- and interfractional motion variation in MR-guided lung SBRT, The British Journal of Radiology, 2018. Crossref

  20. Haskell Melissa W., Cauley Stephen F., Wald Lawrence L., TArgeted Motion Estimation and Reduction (TAMER): Data Consistency Based Motion Mitigation for MRI Using a Reduced Model Joint Optimization, IEEE Transactions on Medical Imaging, 37, 5, 2018. Crossref

  21. Ladd Mark E., Bachert Peter, Meyerspeer Martin, Moser Ewald, Nagel Armin M., Norris David G., Schmitter Sebastian, Speck Oliver, Straub Sina, Zaiss Moritz, Pros and cons of ultra-high-field MRI/MRS for human application, Progress in Nuclear Magnetic Resonance Spectroscopy, 109, 2018. Crossref

  22. Gastl Mareike, Peereboom Sophie M., Fuetterer Maximilian, Boenner Florian, Kelm Malte, Manka Robert, Kozerke Sebastian, Retrospective phase‐based gating for cardiac proton spectroscopy with fixed scan time, Journal of Magnetic Resonance Imaging, 50, 6, 2019. Crossref

  23. Navest R J M, Mandija S, Zijlema S E, Stemkens B, Andreychenko A, Lagendijk J J W, van den Berg C A T, The noise navigator for MRI-guided radiotherapy: an independent method to detect physiological motion, Physics in Medicine & Biology, 65, 12, 2020. Crossref

  24. Tirindelli Maria, Victorova Maria, Esteban Javier, Kim Seong Tae, Navarro-Alarcon David, Zheng Yong Ping, Navab Nassir, Force-Ultrasound Fusion: Bringing Spine Robotic-US to the Next “Level”, IEEE Robotics and Automation Letters, 5, 4, 2020. Crossref

  25. Poblador Rodriguez Esau, Moser Philipp, Auno Sami, Eckstein Korbinian, Dymerska Barbara, Kouwe Andre, Gruber Stephan, Trattnig Siegfried, Bogner Wolfgang, Real‐time motion and retrospective coil sensitivity correction for CEST using volumetric navigators (vNavs) at 7T, Magnetic Resonance in Medicine, 85, 4, 2021. Crossref

  26. Tielemans Birger, Dekoster Kaat, Verleden Stijn E., Sawall Stefan, Leszczyński Bartosz, Laperre Kjell, Vanstapel Arno, Verschakelen Johny, Kachelriess Marc, Verbeken Erik, Swoger Jim, Vande Velde Greetje, From Mouse to Man and Back: Closing the Correlation Gap between Imaging and Histopathology for Lung Diseases, Diagnostics, 10, 9, 2020. Crossref

  27. Darçot Emeline, Yerly Jérôme, Hilbert Tom, Colotti Roberto, Najdenovska Elena, Kober Tobias, Stuber Matthias, Heeswijk Ruud B., Compressed sensing with signal averaging for improved sensitivity and motion artifact reduction in fluorine‐19 MRI, NMR in Biomedicine, 34, 1, 2021. Crossref

  28. Stecker Ian R., Freeman Matthew S., Sitaraman Sneha, Hall Chase S., Niedbalski Peter J., Hendricks Alexandra J., Martin Emily P., Weaver Timothy E., Cleveland Zackary I., Preclinical MRI to quantify pulmonary disease severity and trajectories in poorly characterized mouse models: A pedagogical example using data from novel transgenic models of lung fibrosis, Journal of Magnetic Resonance Open, 6-7, 2021. Crossref

  29. Heerfordt John, Whitehead Kevin K., Bastiaansen Jessica A. M., Di Sopra Lorenzo, Roy Christopher W., Yerly Jérôme, Milani Bastien, Fogel Mark A., Stuber Matthias, Piccini Davide, Similarity‐driven multi‐dimensional binning algorithm (SIMBA) for free‐running motion‐suppressed whole‐heart MRA, Magnetic Resonance in Medicine, 86, 1, 2021. Crossref

  30. Sawaya Reika, Ninomiya Kotoka, Onishi Ryutaro, Arihara Narumi, Tsuji Keiho, Ueda Junpei, Saito Shigeyoshi, In-vivo Evaluation of Bleomycin-induced Lung Fibrosis Model Mouse Using Ultra High-field 7 T-MRI and Micro-CT, Japanese Journal of Radiological Technology, 77, 11, 2021. Crossref

  31. Brablik J., Ladrova Martina, Vilimek Dominik, Kolarik Jakub, Kahankova Radana, Hanzlikova Pavla, Nedoma Jan, Behbehani Khosrow, Fajkus Marcel, Vojtisek Lubomir, Martinek Radek, A Comparison of Alternative Approaches to MR Cardiac Triggering: A Pilot Study at 3 Tesla, IEEE Journal of Biomedical and Health Informatics, 26, 6, 2022. Crossref

  32. Becker Anton S., Rossi Cristina, Renal Arterial Spin Labeling Magnetic Resonance Imaging, Nephron, 135, 1, 2017. Crossref

  33. Ladrova Martina, Martinek Radek, Nedoma Jan, Hanzlikova Pavla, Nelson Michael Douglas, Kahankova Radana, Brablik Jindrich, Kolarik Jakub, Monitoring and Synchronization of Cardiac and Respiratory Traces in Magnetic Resonance Imaging: A Review, IEEE Reviews in Biomedical Engineering, 15, 2022. Crossref

  34. Souza Roberto, Beauferris Youssef, Loos Wallace, Lebel Robert Marc, Frayne Richard, Enhanced Deep-Learning-Based Magnetic Resonance Image Reconstruction by Leveraging Prior Subject-Specific Brain Imaging: Proof-of-Concept Using a Cohort of Presumed Normal Subjects, IEEE Journal of Selected Topics in Signal Processing, 14, 6, 2020. Crossref

  35. Ogier Augustin C., Bustin Aurelien, Cochet Hubert, Schwitter Juerg, van Heeswijk Ruud B., The Road Toward Reproducibility of Parametric Mapping of the Heart: A Technical Review, Frontiers in Cardiovascular Medicine, 9, 2022. Crossref

  36. Wagner Martin G., Periyasamy Sarvesh, Longhurst Colin, McLachlan Matthew J., Whitehead Joseph F., Speidel Michael A., Laeseke Paul F., Real‐time respiratory motion compensated roadmaps for hepatic arterial interventions, Medical Physics, 48, 10, 2021. Crossref

  37. Zhou Yong, Chen Huaping, Ambalavanan Namasivayam, Liu Gang, Antony Veena B., Ding Qiang, Nath Hrudaya, Eary Janet F., Thannickal Victor J., Noninvasive Imaging of Experimental Lung Fibrosis, American Journal of Respiratory Cell and Molecular Biology, 53, 1, 2015. Crossref

  38. Dietrich Sebastian, Aigner Christoph Stefan, Mayer Johannes, Kolbitsch Christoph, Schulz‐Menger Jeanette, Schaeffter Tobias, Schmitter Sebastian, Motion‐compensated fat‐water imaging for 3D cardiac MRI at ultra‐high fields, Magnetic Resonance in Medicine, 87, 6, 2022. Crossref

  39. Polak Daniel, Splitthoff Daniel Nicolas, Clifford Bryan, Lo Wei‐Ching, Huang Susie Y., Conklin John, Wald Lawrence L., Setsompop Kawin, Cauley Stephen, Scout accelerated motion estimation and reduction (SAMER), Magnetic Resonance in Medicine, 87, 1, 2022. Crossref

  40. Lopez Kolkovsky Alfredo L., Carlier Pierre G., Marty Benjamin, Meyerspeer Martin, Interleaved and simultaneous multi‐nuclear magnetic resonance in vivo. Review of principles, applications and potential, NMR in Biomedicine, 35, 10, 2022. Crossref

Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen Preise und Aborichtlinien Begell House Kontakt Language English 中文 Русский Português German French Spain