Corrosion Processes of Physical Vapor Deposition-Coated Metallic Implants
ABSTRAKT
Protecting metallic implants from the harsh environment of physiological fluids is essential to guaranteeing successful long-term use in a patient’s body. Chemical degradation may lead to the failure of an implant device in two different ways. First, metal ions may cause inflammatory reactions in the tissues surrounding the implant and, in extreme cases, these reactions may inflict acute pain on the patient and lead to loosening of the device. Therefore, increasing wear strength is beneficial to the performance of the metallic implant. Second, localized corrosion processes contribute to the nucleation of fatigue cracks, and corrosion fatigue is the main reason for the mechanical failure of metallic implants. Common biomedical alloys such as stainless steel, cobalt-chrome alloys, and titanium alloys are prone to at least one of these problems. Vapor-deposited hard coatings act directly to improve corrosion, wear, and fatigue resistances of metallic materials. The effectiveness of the corrosion protection is strongly related to the structure of the physical vapor deposition layer. The aim of this paper is to present a comprehensive review of the correlation between the structure of physical vapor deposition layers and the corrosion properties of metallic implants.
-
Hunt John A., Chen Rui, Williams David, Bayon Yves, Surgical Materials, in Ullmann's Encyclopedia of Industrial Chemistry, 2012. Crossref
-
Mathew M.T., Nagelli C., Pourzal R., Fischer A., Laurent M.P., Jacobs J.J., Wimmer M.A., Tribolayer formation in a metal-on-metal (MoM) hip joint: An electrochemical investigation, Journal of the Mechanical Behavior of Biomedical Materials, 29, 2014. Crossref
-
Joung Yeun-Ho, Development of Implantable Medical Devices: From an Engineering Perspective, International Neurourology Journal, 17, 3, 2013. Crossref
-
Ching Hee Ay, Choudhury Dipankar, Nine Md Julker, Abu Osman Noor Azuan, Effects of surface coating on reducing friction and wear of orthopaedic implants, Science and Technology of Advanced Materials, 15, 1, 2014. Crossref
-
de Oliveira Mara Cristina Lopes, Ett Gerhard, Antunes Renato Altobelli, Materials selection for bipolar plates for polymer electrolyte membrane fuel cells using the Ashby approach, Journal of Power Sources, 206, 2012. Crossref
-
Antunes R.A., de Oliveira M.C.L., Effect of surface treatments on the fatigue life of magnesium and its alloys for biomedical applications, in Surface Modification of Magnesium and its Alloys for Biomedical Applications, 2015. Crossref
-
Choudhury Dipankar, Roy Taposh, Krupka Ivan, Surface Modifications and Tribological Effect in Orthopedics Implants, in Processing Techniques and Tribological Behavior of Composite Materials, 2015. Crossref
-
Pillis Marina Fuser, Geribola Guilherme Altomari, Scheidt Guilherme, de Araújo Edval Gonçalves, de Oliveira Mara Cristina Lopes, Antunes Renato Altobelli, Corrosion of thin, magnetron sputtered Nb 2 O 5 films, Corrosion Science, 102, 2016. Crossref
-
Antunes R. A., de Oliveira M. C. L., Costa I., Study of the correlation between corrosion resistance and semi-conducting properties of the passive film of AISI 316L stainless steel in physiological solution, Materials and Corrosion, 2011. Crossref
-
McEntire B.J., Bal B.S., Rahaman M.N., Chevalier J., Pezzotti G., Ceramics and ceramic coatings in orthopaedics, Journal of the European Ceramic Society, 35, 16, 2015. Crossref
-
Antunes Renato Altobelli, de Oliveira Mara Cristina Lopes, Corrosion fatigue of biomedical metallic alloys: Mechanisms and mitigation, Acta Biomaterialia, 8, 3, 2012. Crossref
-
Ghosh Subir, Abanteriba Sylvester, Status of surface modification techniques for artificial hip implants, Science and Technology of Advanced Materials, 17, 1, 2016. Crossref
-
Mendizabal L., Bayón R., G-Berasategui E., Barriga J., Gonzalez J.J., Effect of N2 flow rate on the microstructure and electrochemical behavior of TaNx films deposited by modulated pulsed power magnetron sputtering, Thin Solid Films, 610, 2016. Crossref
-
Dziki Jenna L., Huleihel Luai, Scarritt Michelle E., Badylak Stephen F., Extracellular Matrix Bioscaffolds as Immunomodulatory Biomaterials, Tissue Engineering Part A, 23, 19-20, 2017. Crossref
-
Kaur , Ghadirinejad , Oskouei , An Overview on the Tribological Performance of Titanium Alloys with Surface Modifications for Biomedical Applications, Lubricants, 7, 8, 2019. Crossref
-
Fuentes Elena, Alves Sofia, López-Ortega Ainara, Mendizabal Lucía, Sáenz de Viteri Virginia, Advanced Surface Treatments on Titanium and Titanium Alloys Focused on Electrochemical and Physical Technologies for Biomedical Applications, in Biomaterial-supported Tissue Reconstruction or Regeneration, 2019. Crossref
-
Imai Kazuhiro, Zhou Xiao, Liu Xiaoxuan, Application of Zr and Ti-Based Bulk Metallic Glasses for Orthopaedic and Dental Device Materials, Metals, 10, 2, 2020. Crossref
-
Kumar Ashwani, Malik Gaurav, Adalati Ravikant, Chawla Vipin, Pandey Mritunjay Kumar, Chandra Ramesh, Tuning the wettability of highly transparent Nb2O5 nano-sliced coatings to enhance anti-corrosion property, Materials Science in Semiconductor Processing, 123, 2021. Crossref
-
Kmieć Krzysztof, Synder Marek, Kozłowski Piotr, Drobniewski Marek, Sibiński Marcin, Metal debris concentrations in soft tissues adjacent to loosened femoral stems is higher in uncemented than cemented implants, BMC Musculoskeletal Disorders, 15, 1, 2014. Crossref
-
Sivaprakasam P., Kirubel A., Elias G., Maheandera Prabu P., Balasubramani P., Chelladurai Samson Jerold Samuel, Mathematical Modeling and Analysis of Wear Behavior of AlTiN Coating on Titanium Alloy (Ti-6Al-4V), Advances in Materials Science and Engineering, 2021, 2021. Crossref
-
Kaliaraj Gobi Saravanan, Kumar D. Dinesh, Kirubaharan A.M. Kamalan, Bioactive Coatings for Biomedical Applications, in Tribology and Characterization of Surface Coatings, 2022. Crossref
-
Jaiswal Satish, Dubey Anshu, Lahiri Debrupa, Physico-chemical Modifications of Magnesium and Alloys for Biomedical Applications, in Nanoscale Engineering of Biomaterials: Properties and Applications, 2022. Crossref
-
Ahmed I., Ahmad A., Abdul-Rani A. M., Tasnim N., Al-Amin M., A Comparative Review of Surface Modification Technique Between Physical Vapor Deposition (PVD) and Plasma Electrolytic Oxidation (PEO) for Biomedical Applications, in ICPER 2020, 2023. Crossref