Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2012005690
pages 133-144

EXPERIMENTAL STUDY ON NATURAL CONVECTION COOLING OF LED USING A FLAT-PLATE PULSATING HEAT PIPE

Zhi Li
Institute of Thermal Energy Engineering, School of Mechanical, Electronic and Control Engineering, Beijing Jiaotong University, Beijing 100044, China
Li Jia
Institute of Thermal Engineering, School of Mechanical, Electronic and Control Engineering, Beijing Jiaotong University, Beijing 100044, China; Beijing Key Laboratory of Flow and Heat Transfer of Phase Changing in Micro and Small Scale, Beijing 100044, China

ABSTRAKT

Heat dissipation structure is important for high-power LED chips because of a high heat flux. The experimental study of cooling high-power LED (up to 100 W) based on the combination of flat-plate pulsating heat pipe (PHP) and natural convection fins was conducted. The effects of heating power, working fluids, filling ratio (rate of liquid-filled volume to the total volume of channels), configuration parameters, and fin area on the start-up time and the thermal characteristics of the plate PHP were investigated experimentally. The experimental results indicated that cooling by a flat-plate PHP with natural convection fins was effective in lowering the temperature of high-power LED. However, the thermal characteristics of a flat-plate PHP with natural convection cooling possessed large disparity compared to that of forced convection cooling. The optimal filling ratio range was 30% to 50% in this research and the thermal performance of a flat-plate PHP with acetone as a working fluid was better than that with ethanol. Moreover, a flat-plate PHP with a trianglular cross-section channel led to a lower thermal resistance than that with a square cross-section channel. The study of thermal resistance based on channel cross-sectional area was suggested.


Articles with similar content:

A FEASIBILITY STUDY OF APPLYING PULSATING HEAT PIPE IN HEAT SINK
Journal of Enhanced Heat Transfer, Vol.18, 2011, issue 6
Xianyong Zeng, Zirong Lin, Shuangfeng Wang, Eton Lee, Winston Zhang, Yong Tang
Effects of Filling Ratio and Input Heat Flux on the Thermal Performance and Flow Pattern of a Pulsating Heat Pipe
International Heat Transfer Conference 15, Vol.50, 2014, issue
Jungseok Lee, Sung Jin Kim
THERMAL CHARACTERISTICS OF CLOSED LOOP PULSATING HEAT PIPE WITH NANOFLUIDS
Journal of Enhanced Heat Transfer, Vol.18, 2011, issue 3
Sajad Arabnejad, Yadollah Saboohi, M. Behshad Shafii, Hamed Jamshidi
PERFORMANCE CHARACTERISTICS OF FLAT PLATE PULSATING HEAT PIPES WITH MINI- AND MICRO-CHANNELS
Heat Pipe Science and Technology, An International Journal, Vol.5, 2014, issue 1-4
Dong Soo Jang, Yongchan Kim, Eun-Ji Lee
EFFECTS OF CROSS-SECTION GEOMETRY ON THE THERMAL PERFORMANCE OF A PULSATING HEAT PIPE
First Thermal and Fluids Engineering Summer Conference, Vol.15, 2015, issue
Sungwan Park, Jungseok Lee, Sung Jin Kim