Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Heat Transfer Research
Impact-faktor: 0.404 5-jähriger Impact-Faktor: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Druckformat: 1064-2285
ISSN Online: 2162-6561

Volumes:
Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2014006892
pages 311-332

EXPERIMENTAL INVESTIGATION OF A SMALL-SCALE THERMALLY DRIVEN PRESSURIZED ADSORPTION CHILLER

Wai Soong Loh
Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117576
Azhar Bin Ismail
Water Desalination and Reuse Center, 4700 King Abdullah, University of Science and Technology (KAUST), Twuwal 23955-6900
Kim Choon Ng
Department of Mechanical Engineering, National University of Singapore; Water Desalination and Reuse Center, 4700 King Abdullah, University of Science and Technology (KAUST), Twuwal 23955-6900
Won Gee Chun
Department of Nuclear and Energy, Jeju National University, Jeju, Korea

ABSTRAKT

This paper describes the successful operation of an adsorption cycle in a miniaturized adsorption chiller (AD). The experiments show that the bench-scale pressurized adsorption chiller (PAC) has been successfully designed, commissioned, and tested. Experimental results at various heat fluxes, half-cycle operation time intervals, and a cooling load of up to 24 W are also presented. A COP ranging from 0.05 to 0.15 is achieved depending on the parameters of the experimental conditions. Most importantly, the cooling performance of the PAC is achieved at a low encasement temperature that is below ambient. Besides having a high cooling density, the PAC has almost no major moving parts except for the fan of the condenser and it permits quiet operation as compared to other active coolers.


Articles with similar content:

EXPERIMENTAL STUDY OF MINIATURE RADIALLY ROTATING HEAT PIPES WITH WATER AS THE WORKING FLUID
Heat Transfer Research, Vol.45, 2014, issue 2
Jian Ling, Yiding Cao, Brian Reding
RESEARCH ON THE DESIGN IMPROVEMENT OF THERMAL SAFETY IN MULTI-PARALLEL LITHIUM ION BATTERY MODULE
3rd Thermal and Fluids Engineering Conference (TFEC), Vol.1, 2018, issue
Yang Zhao, Chengchao Yuan
THERMAL PERFORMANCE OF A LOW-COST LOOP HEAT PIPE
International Heat Transfer Conference 13, Vol.0, 2006, issue
J. Perez, Jentung Ku, Paul Rogers, H. Nagano
Fuel Cell Co-Generation System with Loop Heat Pipe Based Thermal Control
International Heat Transfer Conference 15, Vol.49, 2014, issue
Masakazu Ohashi, Yuji Saito, Masataka Mochizuki, Zhen Guo, Ehsan B. Haghighi, Randeep Singh, Tien Nguyen, Vijit Wuttijumnong, Thang Nguyen
EXPERIMENTAL COMPARISON OF LOOP HEAT PIPE PERFORMANCE WITH VARIOUS EVAPORATOR DESIGNS
Heat Pipe Science and Technology, An International Journal, Vol.5, 2014, issue 1-4
Valerie Sartre, R. Hodot, Jocelyn Bonjour, T. Barreteau, C. Petit, S. Ouenzerfi, C. Sarno