Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Heat Transfer Research
Impact-faktor: 0.404 5-jähriger Impact-Faktor: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Druckformat: 1064-2285
ISSN Online: 2162-6561

Volumes:
Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2014007549
pages 383-397

EXPERIMENTAL STUDY ON A TWO-STAGE LIQUID DESICCANT DEHUMIDIFICATION SYSTEM USING DUAL DESICCANT SOLUTIONS

Zhenqin Xiong
School of Mechanical Engineering, Shanghai Jiao Tong University
R Z Wang
Shanghai Jiao Tong University
Yanjun Dai
Institute of Refrigeration and Cryogenics, Key Laboratory for Power Machinery and Engineering of M.O.E, Shanghai Jiao Tong University, Shanghai, 200240, China

ABSTRAKT

A two-stage liquid desiccant dehumidification system using a lithium chloride (LiCl) solution and a calcium chloride (CaCl2) solution respectively in the first- and second-stage dehumidifier was proposed through numerical analysis and exergy analysis in the previous study and it is improved by two methods, i.e., the high concentration variance and predehumidification of CaCl2. To assess its dehumidification performance and the predehumidification effect of the first-stage dehumidifier using CaCl2, an experimental study is carried out with dehumidifiers of the size 300 mm × 250 mm × 300 mm packed with Celdeck material under three typical conditions, i.e., ARI standard outdoor conditions, ARI dry outdoor conditions, and the typical summer outdoor conditions in Shanghai. It is proved that the humidity ratio of air after two-stage dehumidification under the ARI standard outdoor conditions and ARI dry outdoor conditions meets the requirement of the ARI indoor conditions when the LiCl concentration is in the range of 40−35% and the initial concentration of CaCl2 is 40%. It is founded that the predehumidification of a CaCl2 solution is significant. It can handle 20−63% of the total moisture load in the case studied. A parametric analysis has also been made. The results indicate that the humidity ratio after dehumidification is mainly influenced by the air velocity and the desiccant concentration of LiCl solution. The dehumidification performance deteriorates when the desiccant solution flow rate is around 300−400 kg/h due to the poor distribution of desiccant solutions on the packing material. The moisture removed by the CaCl2 solution depends on its concentration and the air velocity.


Articles with similar content:

NUMERICAL STUDY ON THERMAL-HYDRAULIC CHARACTERISTIC DEPENDING ON OUTLET ORIFICE SIZE UNDER ACCIDENT CONDITION IN CFVS
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2017, issue
Jong-Wook Lee, Won-Seok Kim
EFFECT OF WATER SPRAYS ON HEAT TRANSFER OF A FIN AND TUBE HEAT EXCHANGER
International Heat Transfer Conference 6, Vol.4, 1978, issue
E. Kach, Dale R. Tree, R.W. Garrett, V.W. Goldschmidt
A Novel Porous Membrane Reactor for a Controllable Butene Oxidative Reaction
Journal of Porous Media, Vol.4, 2001, issue 3
Shanhai Ge, Changhou Liu, Lianjun Wang, Zhihua Li
Bioremediation potential of Spirulina sp.: toxicity and sorption studies of Co and Pb
International Journal on Algae, Vol.7, 2005, issue 2
V. Kalyan Raman, Jayant Doke, V. S. Ghole
AN ADVANCED EVAPORATIVE CONDENSER THROUGH THE MAISOTSENKO CYCLE
International Journal of Energy for a Clean Environment, Vol.12, 2011, issue 2-4
Leland Gillan, David C. Kalensky, Alan Gillan, Aleksandr Kozlov