Abo Bibliothek: Guest
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen
Journal of Long-Term Effects of Medical Implants
SJR: 0.145 SNIP: 0.491 CiteScore™: 0.89

ISSN Druckformat: 1050-6934
ISSN Online: 1940-4379

Journal of Long-Term Effects of Medical Implants

DOI: 10.1615/JLongTermEffMedImplants.2019029265
pages 277-283

RETRACTED
Finite-Element Analysis of Stress and Strain in Mandibular Overdentures Supported by Splinted versus Nonsplinted Implants

Paniz Fasih
Department of Prosthdontics, Dental School, Shahid Behesti University of Medical Sciences, Tehran, Iran
Majid Sedaghat Monfared
Department of Prosthdontics, Dental School, Shahid Behesti University of Medical Sciences, Tehran, Iran
Ardeshir Lafzi
Department of Prosthdontics, Dental School, Shahid Behesti University of Medical Sciences, Tehran, Iran
Amir Mahmoudi Motlagh
Department of Prosthdontics, Dental School, Shahid Behesti University of Medical Sciences, Tehran, Iran
Mohammad Dehghan
Department of Prosthdontics, Dental School, Shahid Behesti University of Medical Sciences, Tehran, Iran
Forouzan Faghani
Department of Prosthdontics, Dental School, Shahid Behesti University of Medical Sciences, Tehran, Iran

ABSTRAKT

RETRACTION STATEMENT: The authors of this retracted article were not the researchers who led the study described therein, and due to interdepartmental miscommunications published the information without permission from or communication with the lead researchers.

The objective of the current study is to investigate the relative effect of splinted and nonsplinted implants on stress and strain in the supporting tissue around implants in two-implant-supported mandibular overdentures. Two models of mandibular overdentures using locators (nonsplinted implants) and bar locators (splinted implants) were constructed, and a vertical load of 100 N was placed on the central fossa of the mandibular first molar. Stress and strain values were obtained using three-dimensional finite-element analysis (ANSYS R18.0). Splinting reduced stress in peri-implant bone in the ipsilateral implant by half and in the contralateral implant by a quarter. Greater stress and a rise in strain from 59 to 79 με in the posterior ridge were also observed with splinting. The model with splinted implants showed more favorable stress distribution in peri-implant bone, perhaps due to better distribution through the bar and the posterior ridge. These findings should be corroborated with clinical studies.


Articles with similar content:

Finite Element Analysis of Stress and Strain in Splinted vs. Non-splinted Implant Supported Mandibular Overdentures
Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 4
Paniz Fasih
Stress and Strain Distribution Patterns in Bone around Splinted Standard and Short Implants Placed at the Crestal Level and Subcrestally using Three- Dimensional Finite Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.27, 2017, issue 1
Raheleh Akhavan Rasoolzadeh, Mahdi Kadkhodazadeh, Amir Mahmoudi Motlagh, Farshad Dehnavi, Reza Amid
Effect of Implant-Abutment Connection Type on Stress Distribution in Peri-Implant Bone and Abutment Micromovement: A Three-Dimensional Finite Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 2
Fariborz Vafaee, Masoumeh Khoshhal, Narges Panahandeh, Parviz Torkzaban, Bahman Tootiaee, Narges Ziaei
Short Dental Implants: A Review of Literature
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 4
Raheleh Rasoolzadeh, Mehi Jafari
EFFECT OF DENTAL IMPLANTOLOGY ON THE BIOMECHANICAL BEHAVIOR OF ALVEOLAR BONE
International Journal for Multiscale Computational Engineering, Vol.16, 2018, issue 6
Bel-Abbes Bachir Bouiadjra, Sohal Mazheralikhan Mohammed, Abdelkader Drai, Abdulmohsen Albedah, Faycal Benyahia, Ali Merdji