Abo Bibliothek: Guest
Journal of Long-Term Effects of Medical Implants

Erscheint 4 Ausgaben pro Jahr

ISSN Druckformat: 1050-6934

ISSN Online: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

Heat Generated by Hip Resurfacing Prostheses: An in Vivo Pilot Study

Volumen 21, Ausgabe 1, 2011, pp. 55-62
DOI: 10.1615/JLongTermEffMedImplants.v21.i1.40
Get accessGet access

ABSTRAKT

In order to determine the magnitude of temperature increases in resurfaced hips, temperature sensors were placed percutaneously in both hip joints of 12 volunteer patients who had 1 or both joints resurfaced. Temperature recordings were made with patients at rest (baseline) and after patients walked for 20 and 60 minutes. The hip resurfacing procedures were performed 12 to 36 months prior to this study using 9 different acetabular bearing surface components. At baseline (resting), a ceramic femoral prosthesis articulating with a poly-ether-ether-ketone (PEEK) acetabular prosthesis generated a temperature increase of 4°C compared to a normal contralateral hip. After 60 minutes of walking, a ceramic femoral prosthesis articulating with a polyurethane acetabular prosthesis generated a temperature increase of 5°C, whereas a ceramic femoral prosthesis articulating with a metal acetabular prosthesis generated a temperature increase of 6°C, a cobalt-chromium alloy femoral prosthesis on a polyethylene acetabular prosthesis generated a temperature increase of 7°C, and a cobalt-chromium alloy metal-on-metal prosthesis generated a temperature increase of 8°C. Resurfaced hips generate more heat than arthritic and normal hips, and arthritic hips generate more heat than normal hips. A resurfaced hip with a ceramic femoral and PEEK or polyurethane acetabulum generated less heat than a resurfaced hip of the same design using a cobalt-chromium femur and either cobalt-chromium, or polyethylene for the acetabulum. Frictional heat generated in a resurfaced hip is not immediately dissipated and may result in increased bearing surface wear. Extended periods of elevated temperature within joints may inhibit periarticular cell growth and perhaps contribute to bone resorption or component loosening over the long term.

SCHLÜSSELWÖRTER: hip resurfacing, heat, joint friction
REFERENZIERT VON
  1. Brockett Claire L., John Gemma, Williams Sophie, Jin Zhongmin, Isaac Graham H., Fisher John, Wear of ceramic-on-carbon fiber-reinforced poly-ether ether ketone hip replacements, Journal of Biomedical Materials Research Part B: Applied Biomaterials, 100B, 6, 2012. Crossref

  2. Uddin M.S., Zhang L.C., Predicting the wear of hard-on-hard hip joint prostheses, Wear, 301, 1-2, 2013. Crossref

  3. Sagbas B., Durakbasa M.N., Effect of surface patterning on frictional heating of vitamin E blended UHMWPE, Wear, 303, 1-2, 2013. Crossref

  4. Sagbas B., Durakbasa M.N., Sagbas M., Koyun A., Measurement and theoretical determination of frictional temperature rise between sliding surfaces of artificial hip joints, Measurement, 51, 2014. Crossref

  5. Sagbas B., Durakbasa M.N., Investigating Effects of Testing Parameters on Frictional Heating of UHMWPE by Taguchi Method, Acta Physica Polonica A, 125, 2, 2014. Crossref

  6. Wang Qian Qian, Wu Jun Jie, Unsworth Anthony, Briscoe Adam, Jarman-Smith Marcus, Lowry Conor, Simpson David, Collins Simon, Biotribological study of large diameter ceramic-on-CFR-PEEK hip joint including fluid uptake, wear and frictional heating, Journal of Materials Science: Materials in Medicine, 23, 6, 2012. Crossref

  7. Pritchett James W., Hip Resurfacing Using Highly Cross-linked Polyethylene: Prospective Study Results at 8.5 Years, The Journal of Arthroplasty, 31, 10, 2016. Crossref

  8. Somogyi Csilla, Matta Csaba, Foldvari Zsofia, Juhász Tamás, Katona Éva, Takács Ádám, Hajdú Tibor, Dobrosi Nóra, Gergely Pál, Zákány Róza, Polymodal Transient Receptor Potential Vanilloid (TRPV) Ion Channels in Chondrogenic Cells, International Journal of Molecular Sciences, 16, 8, 2015. Crossref

  9. Rama Sreekanth P. S., Naresh Kumar N., Arun S., Kanagaraj S., Effect of multi-walled carbon nanotubes reinforcement and gamma irradiation on viscoelastic properties of ultra-high molecular weight polyethylene, Materials Research Innovations, 20, 3, 2016. Crossref

  10. OTSUKA Koichi, HIRAGI Katsuhiro, HIGAKI Hidehiko, Temperature behavior of sliding portions in the wear test of artificial joint materials using a joint simulator and its influence, Transactions of the JSME (in Japanese), 83, 850, 2017. Crossref

  11. Mróz Adrian Bartlomiej, Lapaj Lukasz, Wisniewski Tomasz, Skalski Konstanty, Leshchynsky Volf, Friction and wear of the intervertebral disc endoprosthesis manufactured with use of selective laser melting process, Rapid Prototyping Journal, 23, 6, 2017. Crossref

  12. Tso Chih, Hor Chee, Chen Gooi, Kok Chee, Heat Induction by Viscous Dissipation Subjected to Symmetric and Asymmetric Boundary Conditions on a Small Oscillating Flow in a Microchannel, Symmetry, 10, 10, 2018. Crossref

  13. Pritchett James W, Hip resurfacing with a highly cross-linked polyethylene acetabular liner and a titanium nitride-coated femoral component, HIP International, 28, 4, 2018. Crossref

  14. Cowie Raelene M., Briscoe Adam, Fisher John, Jennings Louise M., Wear and Friction of UHMWPE-on-PEEK OPTIMA™, Journal of the Mechanical Behavior of Biomedical Materials, 89, 2019. Crossref

  15. SREEKANTH P S RAMA, KANAGARAJ S, Influence of MWCNTs and gamma irradiation on thermal characteristics of medical grade UHMWPE, Bulletin of Materials Science, 37, 2, 2014. Crossref

  16. Olsen Ronald S, Lanz Otto I, Revision of a canine Zürich cementless total hip replacement using a ‘Cupless’ system, Veterinary Record Case Reports, 8, 2, 2020. Crossref

  17. Damm Philipp, Bender Alwina, Waldheim Vivian, Winkler Tobias, Duda Georg N., Surgical cup placement affects the heating up of total joint hip replacements, Scientific Reports, 11, 1, 2021. Crossref

  18. Hor C.H., Tso C.P., Chen G.M., Temperature rise by viscous dissipation effect on synovial fluid induced by oscillating motion in artificial hip joint, Case Studies in Thermal Engineering, 24, 2021. Crossref

  19. Fang Xingxing, Li Dahan, Xin Yucheng, Wang Songquan, Guo Yongbo, Hu Ningning, Zhang Dekun, Dynamic contact stress and frictional heat analysis of femoral head-on-acetabular cup interface based on calculation and simulation methods, Industrial Lubrication and Tribology, 73, 10, 2021. Crossref

  20. Uddin M.S., Majewski P., Frictional Heating in Hip Implants – A Review, Procedia Engineering, 56, 2013. Crossref

778 Artikelansichten 30 Artikel-Downloads Metriken
778 ANSICHTEN 30 HERUNTERLADEN 20 Crossref ZITATE Google
Scholar
ZITATE

Artikel mit ähnlichem Inhalt:

Gait Kinematics of Bharatanatyam Dancers with and without Low Back Pain Critical Reviews™ in Physical and Rehabilitation Medicine, Vol.31, 2019, issue 1
Juhi Bharnuke, Rajani Mullerpatan, Claire Hiller
Failure of Cemented Constrained Acetabular Component at the Bipolar Outer Femoral Head Interface in Revision Hip Arthroplasty Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 1
Paula Stritch, Hosam E. Matar, Nicholas Emms
Biomechanical Analysis of CT Scan-based Hip Prosthesis With an Optimal Hip Ball by Using Finite Element Analysis Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 1
D. Sengupta, U.B. Ghosh, Amit Roychowdhury, S. Pal
Strength of Syndesmosis Fixation: Two TightRope versus One TightRope with Plate-and-Screw Construct Journal of Long-Term Effects of Medical Implants, Vol.26, 2016, issue 2
Westley T. Hayes, Robert Pivec, Julio J. Jauregui, Justin Tsai, Marlon McLeold, Subrata Saha, Bhaveen V. Kapadia, Qais Naziri, Jaime A. Uribe
Is CT-A Always Reliable in Detecting Active Bleeding in Closed Pelvic Fractures? Management of a Case with Multiple Closed Pelvic Fratures and Internal Iliac Artery Bleeding Journal of Long-Term Effects of Medical Implants, Vol.32, 2022, issue 4
Iakovos Roupinas, Stamatios Kyriakopoulos, Spyridon J. Maris, Anastasia Vasilopoulou, Stavros Angelis, Antonios Tsanis, Emmanouel Antonogiannakis, Alexandros P. Apostolopoulos, Vasileios Mamalis

Zukünftige Artikel

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen Preise und Aborichtlinien Begell House Kontakt Language English 中文 Русский Português German French Spain