Abo Bibliothek: Guest
Journal of Long-Term Effects of Medical Implants

Erscheint 4 Ausgaben pro Jahr

ISSN Druckformat: 1050-6934

ISSN Online: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

Short Dental Implants: A Review of Literature

Volumen 29, Ausgabe 4, 2019, pp. 261-271
DOI: 10.1615/JLongTermEffMedImplants.2020033390
Get accessGet access

ABSTRAKT

When anatomic structures and ridge resorption limit the placement of a standard implant, the clinician can apply augmentation techniques or use short implants. We conducted a literature review to evaluate the differences in survival rate and the rational use of short implants. Some of the parameters the clinician should consider are (1) area to rehabilitate as well as bone quality, (2) length of the implant, (3) implant diameter, and (4) type of implant and surface treatment. We conducted an electronic search of the PubMed and Google Scholar databases. We also thoroughly evaluated the articles published in the Journal of Periodontology (JOP) and the Journal of Maxillofacial Implants (JOMI) using the key words "implant," "short implant," "finite element analysis," "FEA," "stress-strain distribution," "long imp," and "standard imp." Of the obtained articles, English articles published between 1996 and 2018 were selected for further evaluation. Mechanical factors such as increasing the length and diameter of implants and decreasing the C/I ratio as well as splinting the implants decrease the level of stress in the implant supporting bone. Thus, one or a combination of the aforementioned mechanical factors must be considered in cases where the level of stress in the peri-implant bone needs to be decreased due to the poor quality of bone or use of short implants.

SCHLÜSSELWÖRTER: implant, short dental implant, review
REFERENZEN
  1. Bragger U, Aeschlimann S, Burgin W, Hammerle CHF, Lang NP. Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of function. Clin Oral Impl Res. 2001;12:26-33. .

  2. Atwood DA, Coy WA. Clinical cephalometric and densi ometric study of reduction of residual ridges. J Prosthet Dent. 1971;26:280-95. .

  3. Renouard F, Nisand D. Short implants in the severely resorbed maxilla: A 2-year retrospective clinical study. Clin Implant Dentistry Related Res. 2005;7(S1):S104-S110. .

  4. Mezzomo LA, Miller R, Triches D, Alonso F, Shinkai RS. Meta-analysis of single crowns supported by short (< 10 mm) implants in the posterior region. J Clin Periodontal. 2014;41(2):191-213. .

  5. Mish CE. Short dental implants: A literature review and rationale for use. Dent Today. 2005;24:64-66. .

  6. Olate S, Lyrio MC, de Moraes M. Influence of diameter and length of implants on early dental implant failure. J Maxillafac Surg. 2010;68:414-419. .

  7. Holmgren EP, Seckinger RJ, Kilgren LM, Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis via two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol. 1998;24:80-88. .

  8. Lin C, Wang J, Chang W. Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: A finite element analysis. Clin Oral Implant Res. 2007;19:107-17. .

  9. Summers RB. A new concept in maxillary implant surgery: The osteotome technique. Compendium (Newtown, PA). 1994 Feb;15(2):152-54. .

  10. Felice P, Pistilli R, Lizio G, Pellegrino G, Nisii A, Mar- chetti C. Inlay versus onlay iliac bone grafting in atrophic posterior mandible: A prospective controlled clinical trial for the comparison of two techniques. Clin Implant Dent Relat Res. 2009;11(S1):e69-e82. .

  11. Chiapasco M, Romeo E, Casentini P, Rimondini L. Alveolar distraction osteogenesis vs. vertical guided bone regeneration for the correction of vertically deficient edentulous ridges: A 1-3-year prospective study on humans. Clin Oral Implant Res. 2004;15(1):82-95. .

  12. Garg AK, Morales MJ. Lateralization of the inferior alveolar nerve with simultaneous implant placement: surgical techniques. Pract Periodon Aesth Dent. 1998:10(9) 1197-1204. .

  13. Krekmanov L, Kahn M, Rangert B, Lindstrom H. Tilting of posterior mandibular and maxillary implants for improved prosthesis support. Int J Oral Maxillofac Implants. 2000;15(3):405-414. .

  14. Bedrossian E, Rangert B, Stumpel L, Indresano T. Immediate function with the zygomatic implant: a graftless solution for the patient with mild to advanced atrophy of the maxilla. Int J Oral Maxillofac Implants. 2006;21(6):937-942. .

  15. Tutak M, Smektala T, Schneider K, Gol^biewska E, Sporniak-Tutak K. Short dental implants in reduced alveolar bone height: A review of the literature. Med Sci Monitor: Int Med J Exper Clin Res. 2013;19:1037. .

  16. Shetty S, Puthukkat N, Bhat SV, Shenoy KK. Short implants: A new dimension in rehabilitation of atrophic maxilla and mandible. J Interdisc Dent. 2014 May 1;4(2):66. .

  17. Morand M, Irinakis T. The challenge of implant therapy in the posterior maxilla: Providing a rationale for the use of short implants. J Oral Implantol. 2007;33(5):257-66. .

  18. Nisand D, Renouard F. Short implant in limited bone volume. Periodontol 2000. 2014 Oct;66(1):72-96. .

  19. Adell R, Eriksson B, Lekholm U, Branemark PI, Jemt T. A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int J Oral Maxillofac Implant. 1990 Dec 1;5(4):347-59. .

  20. Lum LB. A biomechanical rationale for the use of short implants. J Oral Implantol. 1991;17(2):126-31. .

  21. Bourauel C, Aitlahrach M, Heinemann F, Hasan I. Bio-mechanical finite element analysis of small diameter and short dental implants: Extensive study of commercial implants. Biomedizinische Technik/Biomed Eng. 2012 Jan 26;57(1):21-32. .

  22. Hasan I, Heinemann F, Aitlahrach M, Bourauel C. Bio mechanical finite element analysis of small diameter and short dental implant. Biomedizinische Technik/Biomed Eng. 2010 Dec 1;55(6):341-50. .

  23. Misch CE, Steigenga J, Barboza E, Misch-Dietsh F, Cianciola LJ, Kazor C. Short dental implants in posterior partial edentulism: A multicenter retrospective 6-year case series study. J Periodontol. 2006 Aug;77(8):1340-47. .

  24. Kotsovilis S, Fourmousis I, Karoussis IK, Bamia C. A systematic review and meta-analysis on the effect of implant length on the survival of rough-surface dental implants. J Periodontol. 2009;80:1700-18. .

  25. Yang TC, Maeda Y, Gonda T. Biomechanical rationale for short implants in splinted restorations: An in vitro study. Int J Prosthodont. 2011;24(2):130-32. .

  26. Duyck J, Van Oosterwyck H, Vander Sloten J, De Cooman M, Puers R, Naert I. Magnitude and distribution of occlusal forces on oral implants supporting fixed prostheses: An in vivo study. Clin Oral Implants Res. 2000 Oct;11(5):465-75. .

  27. Iplikciaglu H, Akfa K. Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone. J Dent. 2002 Jan;30(1):41-46. .

  28. Himmlova L, Dostalova T, Kacovsky A, Konvickova S. Influence of implant length and diameter on stress distribution: A finite element analysis. J Prosth Dent. 2004;91:20-25. .

  29. Vairo G, Sannino G. Comparative evaluation of osseointegrated dental implants based on platform-switching concept: Influence of diameter, length, thread shape, and in-bone positioning depth on stress-based performance. Comput Mathemat Methods Med. 2013;2013. .

  30. Balkaya MC. Investigation of influence of different implant size and placement on stress distribution with three-dimensional finite element analysis. Implant Dent. 2014; 23(6):716-22. .

  31. Toniollo MB, Macedo AP, Rodrigues RC, Ribeiro RF, de Mattos Mda G. Three-dimensional finite element analysis of stress distribution on different bony ridges with different lengths of morse taper implants and prosthesis dimensions. J Craniofac Surg. 2012;23(6):1888-92. .

  32. Baggi L, Cappelloni I, Di Girolamo M, Maceri F, Vairo G. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: A three-dimensional finite element analysis. J Prosthetic Dentistry. 2008 Dec 1;100(6):422-31. .

  33. Chang SH, Lin CL, Lin YS, Hsue SS, Huang SR. Biomechanical comparison of a single short and wide implant with monocortical or bicortical engagement in the atrophic posterior maxilla and a long implant in the augmented sinus. Int J Oral Maxillofac Implants. 2012;27(6):e102-e111. .

  34. Sotto-Maior BS, Senna PM, Silva WJ, Rocha EP, Del Bel Cury AA. Influence of crown-to-implant ratio, retention system, restorative material, and occlusal loading on stress concentrations in single short implants. Int J Oral Maxillofac Implants. 2012 May-Jun;27(3): e13-e18. .

  35. Misch CE. Contemporary implant dentistry. 2nd ed. St. Louis, MO: Wolters Kluwer; 2012. .

  36. Akja K, Iplikfioglu H. Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism. J Oral Rehabil. 2002;29(4):350-56. .

REFERENZIERT VON
  1. Zupancic Cepic Lana, Frank Martin, Reisinger Andreas G., Sagl Benedikt, Pahr Dieter H., Zechner Werner, Schedle Andreas, Experimental validation of a micro-CT finite element model of a human cadaveric mandible rehabilitated with short-implant-supported partial dentures, Journal of the Mechanical Behavior of Biomedical Materials, 126, 2022. Crossref

1776 Artikelansichten 19 Artikel-Downloads Metriken
1776 ANSICHTEN 19 HERUNTERLADEN 1 Crossref ZITATE Google
Scholar
ZITATE

Artikel mit ähnlichem Inhalt:

The Effect of Strength Training on Running Kinematics: A Narrative Review Critical Reviews™ in Physical and Rehabilitation Medicine, Vol.33, 2021, issue 2
Thomas Kernozek, Becky L. Heinert, Charles Nathan Vannatta
Clinical Evaluation of a New Total Hip Prosthetic Design: 100 Consecutive Cementless Total Hip Arthroplasties Using Sulzermedica's "Natural Hip" With Two- to Six-Year Clinical and Radiographic Follow-Up Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 1&2
Thomas B. Pace
Relationship Between Dental Cement Materials of Implant-Supported Crowns with Peri-Implantitis Development in Humans: A Systematic Review of Literature Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 3
Castro Johana, Alfonso Camilo, Hernan Garzon, Cuellar Jefferson, Cifuentes Javier, Torres Nidia, Tocora Camilo
A Systematic Review Investigating the Early Rehabilitation of Patients Following Medial Patellofemoral Ligament Reconstruction for Patellar Instability Critical Reviews™ in Physical and Rehabilitation Medicine, Vol.19, 2007, issue 2
James Walker, Toby O. Smith, Nicola Russell
Effect of Aerobic and Resistance Exercise Training on Balance, Strength, Functional Capacity, and Pulmonary Function in Post-Stroke Patients: A Systematic Review Critical Reviews™ in Physical and Rehabilitation Medicine, Vol.35, 2023, issue 3
Hoda Mohamed Elshiekh Ali, Sampath Kumar Amaravadi

Zukünftige Artikel

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Digitales Portal Digitale Bibliothek eBooks Zeitschriften Referenzen und Berichte Forschungssammlungen Preise und Aborichtlinien Begell House Kontakt Language English 中文 Русский Português German French Spain