Analysis of Sixty-Two Explanted Liotta Bioprostheses: Biocompatibility, Biofunctionality, and Biodurability Issues

Volumen 18, Ausgabe 2, 2008, pp. 91-131
DOI: 10.1615/JLongTermEffMedImplants.v18.i2.10
Get accessGet access

ABSTRAKT

Sixty-two explanted Liotta porcine bioprostheses were examined to review the issues related to their biocompatibility, biofunctionality, and biodurability. These bioprostheses were harvested from 56 patients with implantation times ranging from only a few hours to more than nine years of implantation. There were 10 acute and short-term (< 1 year), 20 midterm (1 < t < 5 years), and 32 long-term (> 5 years) cases. The indications for the reoperations were: hemodynamic (59), thrombosis (10), and endocarditis (3). The major indications varied according to the duration of implantation: blood infiltration, fibrin buildup, thrombosis in the short-term; endocarditis and hemodynamic insufficiency in the midterm; and mineralization and tears causing hemodynamic incompetence in the long term. Mineralization proved to be the main threat to long-term durability for porcine valves. Besides a few short-term failures, these explanted devices slowly degenerated over time and were replaced to prevent congestive heart failure. Documentation of the failure modes of these porcine valves is important since the demand for bioprostheses will increase in the future, in particular for percutaneous devices. Such bioprostheses emphasize a critical biocompatibility issue following implantation because they have the capacity to remain free of thrombus in the absence of anticoagulation. The biofunctionality appears to be adequate in the absence of subsequent pathology with restoration of normal valve function. However, the documentation of such significant long-term biodurability issues raises questions that have been addressed but not fully answered yet with the new generations of bioprostheses.

REFERENZIERT VON
  1. Guidoin R., Zegdi R., Lin J., Mao J., Rochette-Drouin O., How D., Guan X., Bruneval P., Wang L., Germain L., Zhang Z., Transcatheter heart valve crimping and the protecting effects of a polyester cuff, Morphologie, 100, 331, 2016. Crossref

  2. Bourget J.-M., Zegdi R., Lin J., Wawryko P., Merhi Y., Convelbo C., Mao J., Fu Y., Xu T., Merkel N.O., Wang L., Germain L., Zhang Z., Guidoin R., Correlation between structural changes and acute thrombogenicity in transcatheter pericardium valves after crimping and balloon deployment, Morphologie, 101, 332, 2017. Crossref

  3. Guidoin R., Cardiovascular Surgery: Biomaterials, in Reference Module in Materials Science and Materials Engineering, 2017. Crossref

  4. Gauvin Robert, Marinov Georgi, Mehri Yayhe, Klein Julianne, Li Bin, Larouche Danielle, Guzman Randolph, Zhang Ze, Germain Lucie, Guidoin Robert, A comparative study of bovine and porcine pericardium to highlight their potential advantages to manufacture percutaneous cardiovascular implants, Journal of Biomaterials Applications, 28, 4, 2013. Crossref

  5. Rassoli Aisa, Li Yiming, Bao Xianhao, Kawecki Fabien, Zhao Xinzhe, Chappard Daniel, Le-Bel Gaëtan, Feng Jiaxuan, Weber Benedikt, Fatouraee Nasser, Zhang Ze, Jing Zaiping, Germain Lucie, Wang Lu, Guidoin Robert, Donkey pericardium as a select sourcing to manufacture percutaneous heart valves: Decellularization has not yet demonstrated any clear cut advantage to glutaraldehyde treatment, Medicine in Novel Technology and Devices, 4, 2019. Crossref

Neueste Ausgabe

Design and Stability Analysis of an Adaptive Neuro-Fuzzy Inference System (ANFIS)−Based Pacemaker Controller in MATLAB Simulink Asghar Dabiri Aghdam, Nader Jafarnia Dabanloo, Fereidoun Nooshiravan Rahatabad, Keivan Maghooli Complications Following Intraosseous Injections of Calcium Phosphate Bone Cement in Subchondroplasty Christos B. Zachariadis, Helen C. Leligou, Stauros K. Kourkoulis, Evaggelos Magnisalis, Panayiotis J. Papagelopoulos, Olga D. Savvidou Complications Following Short Femoral Nail Fixation for Intertrochanteric Hip Fractures: A Retrospective Study Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, C. Nikakis, Stavros Angelis, Spyridon J. Maris, C. Grekas, Efthymios J. Karadimas, Alexandros P. Apostolopoulos Finite Element Analysis: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Ali Muhsin, Enas Kareem Mohammed, Khalid Bander C-Reactive Protein and Erythrocyte Sedimentation Rates after Total and Unicompartmental Knee Arthroplasty−Less Implant Equals Quicker Normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat Comparison of Roughness, Wettability, and SEM Features between Sandblasted Acid-Etched and Oxidized Titanium Dental Implants Kshitiz Chhabra, Arvina Rajasekar Correlation between Primary Stability of Dental Implants and Bone Density: A Retrospective Analysis S. Padmaja, Arvina Rajasekar

Zukünftige Artikel

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka