图书馆订阅: Guest
Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集
雾化与喷雾
影响因子: 1.737 5年影响因子: 1.518 SJR: 0.814 SNIP: 1.18 CiteScore™: 2.2

ISSN 打印: 1044-5110
ISSN 在线: 1936-2684

卷:
卷 30, 2020 卷 29, 2019 卷 28, 2018 卷 27, 2017 卷 26, 2016 卷 25, 2015 卷 24, 2014 卷 23, 2013 卷 22, 2012 卷 21, 2011 卷 20, 2010 卷 19, 2009 卷 18, 2008 卷 17, 2007 卷 16, 2006 卷 15, 2005 卷 14, 2004 卷 13, 2003 卷 12, 2002 卷 11, 2001 卷 10, 2000 卷 9, 1999 卷 8, 1998 卷 7, 1997 卷 6, 1996 卷 5, 1995 卷 4, 1994 卷 3, 1993 卷 2, 1992 卷 1, 1991

雾化与喷雾

DOI: 10.1615/AtomizSpr.v19.i11.10
pages 997-1012

NEAR-WALL CHARACTERISTICS OF AN IMPINGING GASOLINE SPRAY AT INCREASED AMBIENT PRESSURE AND WALL TEMPERATURE

Jochen Stratmann
Institute of Heat and Mass Transfer, RWTH Aachen University, Germany
D. Martin
Institute of Heat and Mass Transfer, RWTH Aachen University, Eilfschornsteinstr. 18, 52062 Aachen, Germany
P. Unterlechner
Institute of Heat and Mass Transfer, RWTH Aachen University, Eilfschornsteinstr. 18, 52062 Aachen, Germany
Reinhold Kneer
Institute of Heat and Mass Transfer, RWTH Aachen University, Augustinerbach 6, 52062 Aachen, Germany

ABSTRACT

With a focus on the direct-injection gasoline (GDI) engine, this work provides near-wall spray details of the liquid phase of an impinging fuel spray at GDI engine conditions. The experiments are conducted in a constant volume pressure chamber at elevated gas pressure (pgas = 0.6 and 1.5 MPa), increased gas temperature (Tgas = 500 K), and variable wall temperature (Tw = 400 and 575 K). Using phase-Doppler anemometry, temporally and spatially resolved mean droplet sizes and velocity components are determined at distances from 0.2 to 1.0 mm above the surface. The transient behavior of the wall jet, which develops along the surface, is resolved by the measurements. The formation of a vortex at the front of this jet is observed. At its tip, large mean droplet diameters are observed that coincide with a rapid change of the wall-normal velocity. An increasing wall temperature causes the tip of the wall jet to propagate slower along the wall, which is apparently caused by a change in the local density of the gas above the surface.


Articles with similar content:

LIQUID CORE STRUCTURE OF PRESSURE-ATOMIZED SPRAYS VIA LASER TOMOGRAPHIC IMAGING
Atomization and Sprays, Vol.6, 1996, issue 1
A. Mitrovic, T.-W. Lee
THE VISCOUS EFFECT ON THE TRANSIENT DROPLET DEFORMATION PROCESS UNDER THE ACTION OF SHOCK WAVE
Atomization and Sprays, Vol.29, 2019, issue 2
Shuai Shen, Jianling Li, Wei Fan, Chenglong Tang, Jinhong Liu, Xiao Ma
COHERENT STRUCTURES IN THE TURBULENT CHANNEL FLOW WITH DENSITY VARIATION
ICHMT DIGITAL LIBRARY ONLINE, Vol.13, 2008, issue
Takeo Kajishima, Elteyeb Eljack
SHEAR COAXIAL INJECTOR ATOMIZATION PHENOMENA FOR COMBUSTING AND NONCOMBUSTING CONDITIONS
Atomization and Sprays, Vol.6, 1996, issue 2
Robert J. Santoro, H. M. Ryan, Sibtosh Pal, M. J. Foust, M. D. Moser
EXPERIMENTAL STUDY OF THE EFFECTS OF CARBON DIOXIDE CONCENTRATION IN DIESEL FUEL ON SPRAY CHARACTERISTICS
Atomization and Sprays, Vol.18, 2008, issue 5
Zhen Huang, Qiao Xinqi, Jin Xiao