EXPERIMENTAL STUDY OF THE EFFECTS OF VIBRATION AND HORIZONTAL ANGLE ON THE DYNAMICS OF STARTUP AND TRANSIENT REGIMES OF THE HEAT PIPE

卷 2, 册 1-4, 2011, pp. 69-78
DOI: 10.1615/HeatPipeScieTech.v2.i1-4.80
Get accessGet access

摘要

Heat pipes with metal-fibrous capillary structure were studied. The studied frequency range was 10−4000 Hz, the vibration level from 0 to 100 m/s°. Free rotation of the pipe at any angle with respect to the horizontal was provided. Ten thermocouples on the outer surface of the pipe in the heating zone, and three thermocouples on the outer surface of the cooling zone were established. Portholes of glass at the ends of the heat pipe were made. The data of the start-up of the heat pipe are provided. The effect of vibration and tilt angles of the heat pipe on its parameters are shown. It was determined that the slope of the heat pipe α = +30° is optimal. Vibration increases the temperature gradient. It was established that the dynamic properties of the cooling system with heat pipe are determined by external boundary conditions. Heat pipe responds quickly to changes in external boundary conditions, and its thermal resistance varies widely.