图书馆订阅: Guest
Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集
传热学
影响因子: 0.404 5年影响因子: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN 打印: 1064-2285
ISSN 在线: 2162-6561

传热学

DOI: 10.1615/HeatTransRes.2018024938
pages 1705-1720

HEAT AND MASS TRANSFER AND RESISTANCE CHARACTERISTICS OF EVAPORATIVE AIR COOLER WITH HIGH FINNED-TUBE BUNDLES

Qing Zhang
Key Laboratory of Pressure System and Safety, Ministry of Education, East China University of Science and Technology, Shanghai 200237, China
Xuesheng Wang
Key Laboratory of Pressure System and Safety, Ministry of Education, East China University of Science and Technology, Shanghai 200237, China
Weicheng Ruan
Key Laboratory of Pressure System and Safety, Ministry of Education, East China University of Science and Technology, Shanghai 200237, China
Qinzhu Chen
Key Laboratory of Pressure System and Safety, Ministry of Education, East China University of Science and Technology, Shanghai 200237, China
Zilong Liu
Key Laboratory of Pressure System and Safety, Ministry of Education, East China University of Science and Technology, Shanghai 200237, China

ABSTRACT

A theoretical model was suggested and experimental analysis of heat and mass exchange mechanism of a high finned-tube evaporative air cooling device was made. Experiments showed that the heat transfer of the upper four rows of tubes was higher than that of the lower four rows. The upper and lower layers of the proportion of water spray experiments were carried out. In the experimental range, the higher the proportion of the upper water spray, the greater the overall heat transfer. Besides, evaporation and heat transfer of water film were not only related to the air flow and spray water intensity, but also were affected by the relative humidity of imported air, with decrease in the relative humidity of imported air decreased, and with evaporation and heat transfer between air and water film strengthened. According to the experiments, the correlations of evaporation loss and heat transfer were fitted by air flow, spray water intensity, and relative humidity, which showed close agreement with the experimental results to within ± 11% and ± 9%, respectively. The correlation of pressure drop in the high finned-tube bundle was related to air flow rate and the intensity of the spray water, and the fitting error was within ± 8%. This study was instructive for the design of wet air cooler with high finned-tube bundle.


Articles with similar content:

INFLUENCE OF SURFACE WETTABILITY ON HEAT TRANSFER AND PRESSURE DROP CHARACTERISTICS OF WET AIR IN METAL FOAM UNDER DEHUMIDIFYING CONDITIONS
International Heat Transfer Conference 16, Vol.14, 2018, issue
GuoLiang Ding, Zhancheng Lai, Haitao Hu
AERODYNAMIC AND HEAT TRANSFER PERFORMANCE OF AN INDUSTRIAL AIR-COOLED HEAT EXCHANGER
International Heat Transfer Conference 5, Vol.9, 1974, issue
R. A. Stinchcombe, G. H. Cowan, F. R. Dell
Experimental Research of Heat Transfer from an In-Line Tube Bundle to a Vertical Foam Flow
Heat Transfer Research, Vol.40, 2009, issue 5
Jonas Gylys, Irena Gabrielaitiene, Stasys Sinkunas, Tadas Zdankus
REVIEW ON LAMINAR FLOW AND HEAT TRANSFER IN INTERNALLY FINNED TUBES
Journal of Enhanced Heat Transfer, Vol.24, 2017, issue 1-6
Biswadip Shome, Michael K. Jensen
EXPERIMENTAL INVESTIGATION ON CONDENSATION HEAT TRANSFER OF R410A ON SINGLE HORIZONTAL PETAL-SHAPED FINNED TUBE
Journal of Enhanced Heat Transfer, Vol.19, 2012, issue 6
Guo Quan Shi, Tao Xu, Fu Xian Wang, Zheng Guo Zhang