pages 1721-1744

USAGE OF A DIATOMITE-CONTAINING NANOFLUID AS THE WORKING FLUID IN A WICKLESS LOOP HEAT PIPE: EXPERIMENTAL AND NUMERICAL STUDY

Adnan Sözen
Gazi University, Technology Faculty, Energy Systems Engineering, 06500, Ankara, Turkey
Erdem Çiftçi
Gazi University
Selçuk Keçel
Gazi University, Faculty of Architecture, Department of Industrial Product Design, Maltepe, Ankara, Turkey
Metin Gürü
Gazi University, Engineering Faculty, Chemical Engineering, 06500, Ankara, Turkey
Halil Ibrahim Variyenli
Gazi University, Technology Faculty, Energy Systems Engineering, 06500, Ankara, Turkey
Ugur Karakaya
Gazi University, Engineering Faculty, Chemical Engineering Department, Maltepe, Ankara, Turkey

ABSTRACT

In this paper, thermal performance of the diatomite-deionized water nanofluid usage as the working fluid in a wickless loop heat pipe at varying operating conditions was experimentally and numerically investigated. A straight copper tube with an inner diameter of 13 mm, which is of 1 mm wall thickness and 1 m in-length, was used as the thermosyphon in the experimental work. The pipe was charged with deionized water and diatomite-based nanofluid respectively, by one-third of the overall volume of the heat pipe. Diatomite has high absorption capability and thus it can be considerably absorbed by the deionized water. Herewith, the disadvantages of the nanofluids, flocculation and sedimentation, are remarkably annihilated. Moreover, by using a surface-active agent, Triton X-100, these disadvantages were tried to be removed. The experiments were conducted for varying heat loads in evaporator section and cooling water mass flow rates in condenser section of the heat pipe in order to determine the operating parameters under maximum efficiency conditions of the heat pipe. Using experimental findings such performance parameters as efficiency, thermal conductivity, improvement rates in heat transfer were determined and then numerical analysis were performed. The maximum efficiency and the improvement in thermal resistance of the heat pipe when it is filled up with diatomite-based nanofluid in place of deionized water were obtained from the recurrent tests as 14.57%and 43.4%, respectively. Consequently, the experimental and numerical findings were compared to each other and it is pointed out that they are in a good agreement.


Articles with similar content:

PERFORMANCE TESTS OF DEFROSTING PLATES DESIGNED WITH A PULSATING HEAT PIPE (PHP) AS THE HEAT CARRIER
Journal of Enhanced Heat Transfer, Vol.20, 2013, issue 6
Chen-I Chao, Wei-Keng Lin, Huang-Chin Sheng, Mengtan Wang, K. C. Liaw, Ying Chi Yeh, Ting-Yu Hsiung, Shao-Wen Chen, Shou-I Chen
Forced Convective Flow Drag and Heat Transfer Characteristics of CuO Nanoparticle Suspensions and Nanofluids in a Small Tube
Journal of Enhanced Heat Transfer, Vol.17, 2010, issue 1
Liang Liao, Ran Bao, Zhenhua Liu
OSCILLATING BEHAVIOR OF LOOP HEAT PIPE WHEN OPERATING UNDER OVERCHARGED CONDITION
International Heat Transfer Conference 16, Vol.13, 2018, issue
Phuoc Hien Huynh, Akio Miyara, Keishi Kariya, Htoo Kyaw Zin
EXPERIMENTAL INVESTIGATION ON THE HEAT TRANSFER PERFORMANCE OF HEAT PIPES IN COOLING HEV LITHIUM-ION BATTERIES
Heat Transfer Research, Vol.49, 2018, issue 17
Mohd Zulkifly Abdullah, Mohd A. Ismail, Faiza M. Nasir
Determination of the Optimum Droplet Size and Operation Condition for Minimum Drift
International Journal of Fluid Mechanics Research, Vol.24, 1997, issue 4-6
J.-So. Park, L. E. Bode, J.-Yo. Rhee