图书馆订阅: Guest
Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集
传热学
影响因子: 1.199 5年影响因子: 1.155 SJR: 0.267 SNIP: 0.503 CiteScore™: 1.4

ISSN 打印: 1064-2285
ISSN 在线: 2162-6561

卷:
卷 51, 2020 卷 50, 2019 卷 49, 2018 卷 48, 2017 卷 47, 2016 卷 46, 2015 卷 45, 2014 卷 44, 2013 卷 43, 2012 卷 42, 2011 卷 41, 2010 卷 40, 2009 卷 39, 2008 卷 38, 2007 卷 37, 2006 卷 36, 2005 卷 35, 2004 卷 34, 2003 卷 33, 2002 卷 32, 2001 卷 31, 2000 卷 30, 1999 卷 29, 1998 卷 28, 1997

传热学

DOI: 10.1615/HeatTransRes.2014006892
pages 311-332

EXPERIMENTAL INVESTIGATION OF A SMALL-SCALE THERMALLY DRIVEN PRESSURIZED ADSORPTION CHILLER

Wai Soong Loh
Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117576
Azhar Bin Ismail
Water Desalination and Reuse Center, 4700 King Abdullah, University of Science and Technology (KAUST), Twuwal 23955-6900
Kim Choon Ng
Department of Mechanical Engineering, National University of Singapore; Water Desalination and Reuse Center, 4700 King Abdullah, University of Science and Technology (KAUST), Twuwal 23955-6900
Won Gee Chun
Department of Nuclear and Energy, Jeju National University, Jeju, Korea

ABSTRACT

This paper describes the successful operation of an adsorption cycle in a miniaturized adsorption chiller (AD). The experiments show that the bench-scale pressurized adsorption chiller (PAC) has been successfully designed, commissioned, and tested. Experimental results at various heat fluxes, half-cycle operation time intervals, and a cooling load of up to 24 W are also presented. A COP ranging from 0.05 to 0.15 is achieved depending on the parameters of the experimental conditions. Most importantly, the cooling performance of the PAC is achieved at a low encasement temperature that is below ambient. Besides having a high cooling density, the PAC has almost no major moving parts except for the fan of the condenser and it permits quiet operation as compared to other active coolers.


Articles with similar content:

AN EXPERIMENTAL INVESTIGATION OF PHASE CHANGE MATERIAL (PCM) FOR HEAT MANAGEMENT OF INSTRUMENTS
Heat Pipe Science and Technology, An International Journal, Vol.5, 2014, issue 1-4
Sameer Khandekar, A. K. Sahani, J. K. Bajpai, Pankaj Srivastava
DYNAMIC TESTING OF A CRYOGENIC HEAT PIPE/RADIATOR
International Heat Transfer Conference 6, Vol.3, 1978, issue
B.E. Nelson , J.T. Chuvala, A.A. Cenkner, Jr.
STUDY ON THE PERFORMANCE OF AN ADVANCED WATER-COOLED HEAT SINK USING A THERMOSYPHON MECHANISM FOR ELECTRONIC DEVICES
Heat Pipe Science and Technology, An International Journal, Vol.1, 2010, issue 3
Fumito Kaminaga, Kunihito Matsumura
Thermal Performance of a Passive Immersion-Cooling Multichip Module
Journal of Enhanced Heat Transfer, Vol.2, 1995, issue 1-2
Avram Bar-Cohen, Tetsuo Ogata, David Kitching
RAILWAYS QUALIFICATION TESTS OF A CAPILLARY PUMPED LOOP ON A TRAIN
Heat Pipe Science and Technology, An International Journal, Vol.5, 2014, issue 1-4
V. Dupont, L. Barremaecker, Sebastien Nicolau, S. Van Oost