图书馆订阅: Guest
Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集
传热学
影响因子: 0.404 5年影响因子: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN 打印: 1064-2285
ISSN 在线: 2162-6561

传热学

DOI: 10.1615/HeatTransRes.2014007549
pages 383-397

EXPERIMENTAL STUDY ON A TWO-STAGE LIQUID DESICCANT DEHUMIDIFICATION SYSTEM USING DUAL DESICCANT SOLUTIONS

Zhenqin Xiong
School of Mechanical Engineering, Shanghai Jiao Tong University
Ruzhu Wang
Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, 800 Dongchuan Road. Minhang District, Shanghai 200240, China
Yanjun Dai
Institute of Refrigeration and Cryogenics, Key Laboratory for Power Machinery and Engineering of M.O.E, Shanghai Jiao Tong University, Shanghai, 200240, China

ABSTRACT

A two-stage liquid desiccant dehumidification system using a lithium chloride (LiCl) solution and a calcium chloride (CaCl2) solution respectively in the first- and second-stage dehumidifier was proposed through numerical analysis and exergy analysis in the previous study and it is improved by two methods, i.e., the high concentration variance and predehumidification of CaCl2. To assess its dehumidification performance and the predehumidification effect of the first-stage dehumidifier using CaCl2, an experimental study is carried out with dehumidifiers of the size 300 mm × 250 mm × 300 mm packed with Celdeck material under three typical conditions, i.e., ARI standard outdoor conditions, ARI dry outdoor conditions, and the typical summer outdoor conditions in Shanghai. It is proved that the humidity ratio of air after two-stage dehumidification under the ARI standard outdoor conditions and ARI dry outdoor conditions meets the requirement of the ARI indoor conditions when the LiCl concentration is in the range of 40−35% and the initial concentration of CaCl2 is 40%. It is founded that the predehumidification of a CaCl2 solution is significant. It can handle 20−63% of the total moisture load in the case studied. A parametric analysis has also been made. The results indicate that the humidity ratio after dehumidification is mainly influenced by the air velocity and the desiccant concentration of LiCl solution. The dehumidification performance deteriorates when the desiccant solution flow rate is around 300−400 kg/h due to the poor distribution of desiccant solutions on the packing material. The moisture removed by the CaCl2 solution depends on its concentration and the air velocity.


Articles with similar content:

A NOVEL MULTILAYER DESICCANT DEHUMIDIFIER FOR HYBRID AIR-CONDITIONING: ADSORPTION AND DESORPTION IN MACRO SCALE
International Heat Transfer Conference 16, Vol.23, 2018, issue
Wei-Lun Hsu, Hirofumi Daiguji, Soumyadeep Paul, Kenji Kitaoka, Jubair A. Shamim
Farming of the Juvenile Narrow-clawed Crayfish (Astacus leptodactylus) in Cages and Ponds in Polyculture With Fish in the Heated Waste Water of the Thermal Power Plant
Hydrobiological Journal, Vol.46, 2010, issue 3
V. F. Kulesh, A. V. Alekhnovych
SIMULATION OF WETTABILITY EFFECTS ON GAS-WATER FLOW IN POROUS MEDIA
International Heat Transfer Conference 16, Vol.5, 2018, issue
Bohao Wu, Yu Liu, Yongchen Song, Dayong Wang, Meiheriayi Mutailipu
EXERGY ANALYSIS OF A DC PLASMA SPRAYING OF POLYMER/Al203 COMPOSITE COATING
Progress in Plasma Processing of Materials, 1999, Vol.1, 1999, issue
D. Gravelle, K. Y. Tufa, Francois Gitzhofer
Thermodynamics analysis of hydrogen production via NiFe2O4/NiO-FeO redox reaction
Second Thermal and Fluids Engineering Conference, Vol.33, 2017, issue
Yuan Yuan, Li Bingxi, Yong Shuai, Huang Xing, Hong Jiarong, Tan Heping