The Impact Factor measures the average number of citations received in a particular year by papers published in the journal during the two preceding years. 2017 Journal Citation Reports (Clarivate Analytics, 2018) IF: 1.7 To calculate the five year Impact Factor, citations are counted in 2017 to the previous five years and divided by the source items published in the previous five years. 2017 Journal Citation Reports (Clarivate Analytics, 2018) 5-Year IF: 1.4 The Immediacy Index is the average number of times an article is cited in the year it is published. The journal Immediacy Index indicates how quickly articles in a journal are cited. Immediacy Index: 0.6 The Eigenfactor score, developed by Jevin West and Carl Bergstrom at the University of Washington, is a rating of the total importance of a scientific journal. Journals are rated according to the number of incoming citations, with citations from highly ranked journals weighted to make a larger contribution to the eigenfactor than those from poorly ranked journals. Eigenfactor: 0.00072 The Journal Citation Indicator (JCI) is a single measurement of the field-normalized citation impact of journals in the Web of Science Core Collection across disciplines. The key words here are that the metric is normalized and cross-disciplinary. JCI: 0.43 SJR: 0.318 SNIP: 0.568 CiteScore™:: 3.5 H-Index: 28

Indexed in

DEPENDENCE OF WATER TEMPERATURE GRADIENT ON CONDENSATION IN STRATIFIED TWO-PHASE FLOW

卷 47, 册 12, 2016, pp. 1157-1168
DOI: 10.1615/HeatTransRes.2016014072
Get accessGet access

摘要

The dependence of water behavior on condensing steam was examined in stratified cocurrent two-phase flow in a relatively short and narrow horizontal rectangular channel. The main scope of investigation was the process of heat removal from the horizontal water surface to the bulk. A high resolution IR measurement technique was employed to measure the water temperature field. Experiments were conducted at different inflow velocities of steam (6, 8, 10, and 12 m/s) and water (0.014, 0.028, 0.042, and 0.056 m/s). The data analysis was performed by comparing calculated vertical thermal gradients of water, bulk heating power distribution, density of steam condensation mass flux, and a modified Jacob criterion. The results showed very strong dependence of condensation on the steam velocity. The optimal condensation regime was found at a steam-to-water velocity ratio of 300–400.

对本文的引用
  1. Gasiunas Stasys, Seporaitis Marijus, Almenas Kazys, Turbulence predicting criterion based on shear forces at the boundaries in a two-phase flow, International Journal of Thermal Sciences, 135, 2019. Crossref

Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集 订购及政策 Begell House 联系我们 Language English 中文 Русский Português German French Spain