Radial Versus Dorsal Ulnar Cutaneous Sensory Studies

卷 16, 册 5, 2006, pp. 349-358
DOI: 10.1615/JLongTermEffMedImplants.v16.i5.40
Get accessGet access

摘要

Peripheral nerves injuries are unfortunately common. Neuropathy may result from trauma, entrapment, metabolic or hereditary disturbances, inflammatory processes, iatrogenic injury from medical implants, and several other causes. We set out to create a large normative database for radial and dorsal ulnar cutaneous (DUC) sensory studies. Because comparison between two nerves of the same limb can be useful in detecting pathology, we also compared the latencies between the two nerves.
Data were collected on both nerves using a 10-cm antidromic technique while controlling for temperature. Included subjects were asymptomatic: radial sensory studies were performed on 212 volunteers, DUC sensory studies were performed on 194 volunteers, and both studies were performed on 159 volunteers. Data were collected for onset and peak latencies, onset-to-peak and peak-to-peak amplitudes, area, rise time, and duration. Side-to-side differences were investigated. The data were analyzed to determine whether age, race, gender, height, weight, or body mass index (BMI) (kg/m2) correlated with different results. Differences in latencies between the nerves were analyzed as were side-to-side differences.
Mean values for radial and DUC nerves, respectively, were found to be as follows: onset latency 1.9 ± 0.2 ms and 1.8 ± 0.3 ms, peak latency 2.4 ± 0.2 ms and 2.3 ± 0.4 ms, onset-to-peak amplitude 29 ± 13 μV and 17 ± 10 μV, peak-to-peak amplitude 33 ± 14 μV and 20 ± 13 μV, and area 18 ± 7 nVs and 11 ± 7 nVs. Mean rise time (0.5 ± 0.1 ms) and duration (1.2 ± 0.2 ms) were identical for both nerves. The upper limit of normal (ULN) side-to-side difference in peak latency was 0.3 ms for the radial and 0.4 ms for the DUC study. The ULN drop in peak-to-peak amplitude from one side to the other was 54% for the radial and 67% for the ulnar study. Increasing age, male gender, and increasing BMI (radial only) were associated with lower amplitudes and area, though the effects were clinically insignificant. The ULN increase in both radial-versus-DUC and DUC-versus-radial peak latency was 0.4 ms.
In conclusion, a large normative database for the radial and DUC sensory studies has been derived that will assist in the diagnosis of peripheral neuropathy from a variety of etiologies. Side-to-side and internerve comparisons were also made.

对本文的引用
  1. Chen Shan, Andary Michael, Buschbacher Ralph, Del Toro David, Smith Benn, So Yuen, Zimmermann Kuno, Dillingham Timothy R., Electrodiagnostic reference values for upper and lower limb nerve conduction studies in adult populations, Muscle & Nerve, 54, 3, 2016. Crossref

最新一期

Design and Stability Analysis of an Adaptive Neuro-Fuzzy Inference System (ANFIS)−Based Pacemaker Controller in MATLAB Simulink Asghar Dabiri Aghdam, Nader Jafarnia Dabanloo, Fereidoun Nooshiravan Rahatabad, Keivan Maghooli Complications Following Intraosseous Injections of Calcium Phosphate Bone Cement in Subchondroplasty Christos B. Zachariadis, Helen C. Leligou, Stauros K. Kourkoulis, Evaggelos Magnisalis, Panayiotis J. Papagelopoulos, Olga D. Savvidou Complications Following Short Femoral Nail Fixation for Intertrochanteric Hip Fractures: A Retrospective Study Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, C. Nikakis, Stavros Angelis, Spyridon J. Maris, C. Grekas, Efthymios J. Karadimas, Alexandros P. Apostolopoulos Finite Element Analysis: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Ali Muhsin, Enas Kareem Mohammed, Khalid Bander C-Reactive Protein and Erythrocyte Sedimentation Rates after Total and Unicompartmental Knee Arthroplasty−Less Implant Equals Quicker Normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat Comparison of Roughness, Wettability, and SEM Features between Sandblasted Acid-Etched and Oxidized Titanium Dental Implants Kshitiz Chhabra, Arvina Rajasekar Correlation between Primary Stability of Dental Implants and Bone Density: A Retrospective Analysis S. Padmaja, Arvina Rajasekar

将发表的论文

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka