Protein Interactions with Endovascular Prosthetic Surfaces
摘要
Blood protein interaction with prosthetic surfaces seems to be the initial step in the chain of events leading to tissue incorporation of endovascular devices. This paper focuses on the relationship between surface free energy and protein adsorption on metals and polymers commonly used for fabricating vascular prosthetic devices. Our results support a relationship between surface energy and protein adsorption. Albumin was more easily eluted than fibrinogen and fibronectin from most metals and all polymeric surfaces considered. Following elution, metals retained a larger fraction of protein as compared to polymers.
-
Jiménez Juan M., Davies Peter F., Hemodynamically Driven Stent Strut Design, Annals of Biomedical Engineering, 37, 8, 2009. Crossref
-
Sarra-Bournet C, Turgeon S, Mantovani D, Laroche G, A study of atmospheric pressure plasma discharges for surface functionalization of PTFE used in biomedical applications, Journal of Physics D: Applied Physics, 39, 16, 2006. Crossref
-
Charonko John, Karri Satyaprakash, Schmieg Jaime, Prabhu Santosh, Vlachos Pavlos, In Vitro, Time-Resolved PIV Comparison of the Effect of Stent Design on Wall Shear Stress, Annals of Biomedical Engineering, 37, 7, 2009. Crossref
-
Yeh Hung-I, Lu Shao-Kou, Tian Tin-Yi, Hong Ray-Ching, Lee Wun-Hsing, Tsai Cheng-Ho, Comparison of endothelial cells grown on different stent materials, Journal of Biomedical Materials Research Part A, 76A, 4, 2006. Crossref
-
Beier Florian, Gyöngyösi Mariann, Raeder Thomas, von Eckardstein-Thumb Eva, Sperker Werner, Albrecht Peter, Spes Christoph, Glogar Dietmar, Mudra Harald, First in–human randomized comparison of an anodized niobium stent versus a standard stainless steel stent, Clinical Research in Cardiology, 95, 9, 2006. Crossref
-
Patrzyk Maciej, Hoene Andreas, Jarchow Raymond, Wilhelm Lutz, Walschus Uwe, Zippel Roland, Schlosser Michael, Time course of fibronectin in the peri-implant tissue and neointima formation after functional implantation of polyester-based vascular prostheses with different porosity in pigs, Biomedical Materials, 5, 5, 2010. Crossref
-
Stampfl Ulrike, Sommer Christof-Matthias, Thierjung Heidi, Stampfl Sibylle, Lopez-Benitez Ruben, Radeleff Boris, Berger Irina, Richter Goetz M., Reduction of Late In-Stent Stenosis in a Porcine Coronary Artery Model by Cobalt Chromium Stents with a Nanocoat of Polyphosphazene (Polyzene-F), CardioVascular and Interventional Radiology, 31, 6, 2008. Crossref
-
Choubey Animesh, Marton Denes, Sprague Eugene A., Human aortic endothelial cell response to 316L stainless steel material microstructure, Journal of Materials Science: Materials in Medicine, 20, 10, 2009. Crossref
-
Hamilos Michalis, Ribichini Flavio, Ostojic Miodrag C., Ferrero Valeria, Orlic Dejan, Vassanelli Corrado, Karanovic Nevena, Sarno Giovanna, Cuisset Thomas, Vardas Panos E., Wijns William, Coronary Vasomotion One Year after Drug-Eluting Stent Implantation: Comparison of Everolimus-Eluting and Paclitaxel-Eluting Coronary Stents, Journal of Cardiovascular Translational Research, 7, 4, 2014. Crossref
-
Palmaz Julio C., The 2001 Charles T. Dotter Lecture: Understanding Vascular Devices at the Molecular Level Is the Key to Progress, Journal of Vascular and Interventional Radiology, 12, 7, 2001. Crossref
-
Bayes-Genis Antoni, Camrud Allan R, Jorgenson Michael, Donovan Janis, Shogren Kristin L, Holmes David R, Schwartz Robert S, Pressure rinsing of coronary stents immediately before implantation reduces inflammation and neointimal hyperplasia, Journal of the American College of Cardiology, 38, 2, 2001. Crossref
-
Melchiorri Anthony J., Hibino Narutoshi, Fisher John P., Strategies and Techniques to Enhance theIn SituEndothelialization of Small-Diameter Biodegradable Polymeric Vascular Grafts, Tissue Engineering Part B: Reviews, 19, 4, 2013. Crossref
-
Suttorp M. J., Stella P. R., Dens J., McKenzie J. M., Park K. S., Frambach P., Ultra-thin strut cobalt chromium bare metal stent usage in a complex real-world setting. (SOLSTICE registry), Netherlands Heart Journal, 23, 2, 2015. Crossref
-
Goh Ee, Wong Eleanor, Farhatnia Yasmin, Tan Aaron, Seifalian Alexander, Accelerating in Situ Endothelialisation of Cardiovascular Bypass Grafts, International Journal of Molecular Sciences, 16, 1, 2014. Crossref
-
Thierry Benjamin, Tabrizian Maryam, Biocompatibility and Biostability of Metallic Endovascular Implants: State of the Art and Perspectives, Journal of Endovascular Therapy, 10, 4, 2003. Crossref
-
Regar E, Sianos G, Serruys P W, Stent development and local drug delivery, British Medical Bulletin, 59, 1, 2001. Crossref
-
Thierry Benjamin, Tabrizian Maryam, Biocompatibility and Biostability of Metallic Endovascular Implants:State of the Art and Perspectives, Journal of Endovascular Therapy, 10, 4, 2003. Crossref
-
Russo Riccardo, Bradac Gianni Boris, Castellan Lucio, Gallesio Ivan, Garbossa Diego, Iannucci Giuseppe, Mardighian Dikran, Menozzi Roberto, Pitrone Antonio, Romano Giuseppe, Venturi Fabrizio, Bergui Mauro, Neuroform Atlas stent-assisted coiling of ruptured intracranial aneurysms: A multicenter study, Journal of Neuroradiology, 48, 6, 2021. Crossref