图书馆订阅: Guest
器官移植长期效应期刊

每年出版 4 

ISSN 打印: 1050-6934

ISSN 在线: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

Ease of Donning of New Powder-Free Non-Latex and Latex Double-Glove Hole Puncture Indication Systems

卷 13, 册 2, 2003, 6 pages
DOI: 10.1615/JLongTermEffMedImplants.v13.i2.30
Get accessGet access

摘要

Cornstarch on surgical gloves is often used as a detackifying agent and a lubricant to facilitate glove donning. During the last century, scientific studies have demonstrated that cornstarch produces tissue injury in literally every part of the body. Because this glove lubricant cannot be removed from the glove, Dr. David Podell, an ophthalmologic surgeon, and his cousin, Howard Podell, a chemical engineer, devised the first powder-free surgical glove that could be donned easily. They coated the inner surface of the surgical glove with a methacrylate polymer lining that was bonded to the natural rubber latex. This special coating acts as a lubricant to facilitate donning with damp, wet, or dry hands. In our earlier experimental studies, we confirmed that these polymer-lined latex gloves could be donned with either wet or dry hands. More recently, the polymer-coated latex gloves were incorporated into a double-glove hole puncture indication system that accurately detected glove holes in the presence of fluid. Because this discovery has been expanded into the development of a non-latex double-glove hole puncture indication system, we have expanded our biomechanical performance studies to examine the glove donning forces of the latex and non-latex glove hole puncture indication systems. The maximum donning forces recorded for the non-latex undergloves were significantly lower than those encountered by the same respective sizes of the latex underglove. The donning forces of the thin Biogel® Super-SensitiveTM outer gloves were remarkably similar to the donning forces of the Biogel® IndicatorTM undergloves. The thicker Biogel® outer gloves encountered greater donning forces than that noted for the Biogel® Super-SensitiveTM outer gloves. The donning forces recorded for the non-latex outer gloves were remarkably similar to those noted for the latex Biogel® outer gloves. Because the results of this biomechanical performance study demonstrated that the latex and non-latex double-glove hole puncture indication systems can be easily donned by surgeons using relatively low donning forces, this study provides convincing evidence that these double-glove hole puncture indication systems can be used in all surgical procedures.

对本文的引用
  1. Caillot Jean-Louis, Paparel Philippe, Arnal Eric, Schreiber Vincent, Voiglio Eric J., Anticipated Detection of Imminent Surgeon–Patient Barrier Breaches. A Prospective Randomized Controlled Trial Using an Indicator Underglove System, World Journal of Surgery, 30, 1, 2006. Crossref

  2. Caillot J.L., Le gantage chirurgical en France : une évolution lente mais nécessaire, Journal de Chirurgie, 142, 4, 2005. Crossref

  3. Preece Daniel, Hong Ng Thian, Tong Heam Kit, Lewis Roger, Carré Matt J., The effects of chlorination, thickness, and moisture on glove donning efficiency, Ergonomics, 64, 9, 2021. Crossref

将发表的论文

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Begell Digital Portal Begell 数字图书馆 电子图书 期刊 参考文献及会议录 研究收集 订购及政策 Begell House 联系我们 Language English 中文 Русский Português German French Spain